BACKGROUND The delineation of pancreatic tumors on CT is challenging. In this study, we quantified the interobserver variation for pancreatic tumor delineation on 3DCT as well as on 4DCT. METHODS Eight observers (radiation oncologists) from six institutions delineated pancreatic tumors of four patients with (borderline) resectable pancreatic cancer. The study consisted of two stages. In the 3DCT-stage, the gross tumor volume (GTV) was delineated on a contrast-enhanced scan. In the 4DCT-stage, the internal GTV (iGTV) was delineated, accounting for the respiratory motion. We calculated the volumes of the (i)GTV, the overlap of the delineated volumes (expressed as generalized conformity index: CIgen), the local observer variation (local standard deviation: SD) and the overall observer variation (overall SD). We compared these results between GTVs and iGTVs. Additionally, observers were asked to fill out a questionnaire concerning the difficulty of the delineation and their experience in delineating pancreatic tumors. RESULTS The ratios of the largest to the smallest delineated GTV and iGTV within the same patient were 6.8 and 16.5, respectively. As the iGTV incorporates the GTV during all respiratory phases, the mean volumes of the iGTV (40.07 cm3) were larger than those of the GTV (29.91 cm3). For all patients, CIgen was larger for the iGTV than for the GTV. The mean overall observer variation (root-mean-square of all local SDs over four patients) was 0.63 cm and 0.80 cm for GTV and iGTV, respectively. The largest local observer variations were seen close to biliary stents and suspicious pathological enlarged lymph nodes, as some observers included them and some did not. This variation was more pronounced for the iGTV than for the GTV. The observers rated the 3DCT-stage and 4DCT-stage equally difficult and treated on average three to four pancreatic cancer patients per year. CONCLUSIONS A considerable interobserver variation in delineation of pancreatic tumors was observed. This variation was larger for 4D than for 3D delineation. The largest local observer variation was found around biliary stents and suspicious pathological enlarged lymph nodes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Addition of MRI for CT-based pancreatic tumor delineation: a feasibility study.

PURPOSE To assess the effect of additional magnetic resonance imaging (MRI) alongside the planning computed tomography (CT) scan on target volume delineation in pancreatic cancer patients. MATERIAL AND METHODS Eight observers (radiation oncologists) from six institutions delineated the gross tumor volume (GTV) on 3DCT, and internal GTV (iGTV) on 4DCT of four pancreatic cancer patients, while ...

متن کامل

Geometrical differences in gross target volumes between 3DCT and 4DCT imaging in radiotherapy for non-small-cell lung cancer

The aim of this study was to explore the characteristic of 3DCT scanning phases and estimate the comparative amount of respiration motion information included in 3DCT and 4DCT by comparing the volumetric and positional difference between the volumes from 3DCT and 4DCT for the radiotherapy of non-small-cell lung cancer (NSCLC). A total of 28 patients with NSCLC sequentially underwent 3DCT and 4D...

متن کامل

Inter-observer variability of clinical target volume delineation in radiotherapy treatment of pancreatic cancer: a multi-institutional contouring experience

BACKGROUND An observational multi-institutional study has been conducted aimed to evaluate the inter-observer variability in clinical target volume (CTV) delineation among different radiation oncologists in radiotherapy treatment of pancreatic cancer. METHODS A multi-institutional contouring dummy-run of two different cases of pancreatic cancer treated by postoperative and preoperative radiot...

متن کامل

Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation

BACKGROUND To explore the interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on the four-dimensional computed tomography (4DCT) scan for external-beam partial breast irradiation (EB-PBI) during free breathing. METHODS Patients with a seroma clarity score (SCS) 3 ~ 5 and ≥5 surgical clips in the lumpectomy cavity after breast-conserving surgery...

متن کامل

Comparative evaluation of CT-based and PET/4DCT-based planning target volumes in the radiation of primary esophageal cancer.

PURPOSE To compare planning target volume (PTV) defined by PET combined with 4DCT to 3DCT and 4DCT. METHODS Eighteen (18/30) esophageal cancer patients who underwent 3DCT, 4DCT and (18)F-FDG PET-CT thoracic simulation with SUVmax≥2.0 of the primary volume were enrolled. CTV3D was formed on 3DCT by adding a margin of 30 mm in cranial-caudal direction and 5 mm in transversal direction. PTV3D wa...