Continuous wave ultrasonic Doppler tomography.

نویسندگان

  • Haidong-Dong Liang
  • Chun Sing Louis Tsui
  • Michael Halliwell
  • Peter N T Wells
چکیده

In continuous wave ultrasonic Doppler tomography (DT), the ultrasonic beam moves relative to the scanned object to acquire Doppler-shifted frequency spectra which correspond to cross-range projections of the scattering and reflecting structures within the object. The relative motion can be circular or linear. These data are then backprojected to reconstruct the two-dimensional image of the object cross section. By using coherent processing, the spatial resolution of ultrasonic DT is close to an order of magnitude better than that of traditional pulse-echo imaging at the same ultrasound frequency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasonic imaging of the human body

Ultrasonic imaging is a mature medical technology. It accounts for one in four imaging studies and this proportion is increasing. Wave propagation, beam formation, the Doppler effect and the properties of tissues that affect imaging are discussed. The transducer materials and construction of the probes used in imaging are described, as well as the methods of measuring the ultrasonic field. The ...

متن کامل

Duplex scanning in extracranial vertebral artery dissection.

Ultrasonic (duplex scanning and continuous-wave Doppler) and angiographic findings in three patients with bilateral extracranial vertebral artery dissection are reported. A pattern of ultrasonic anomalies diagnostic of dissection is described, including association of a localized increase in diameter of the artery with hemodynamic signs of stenosis or occlusion at the same level and decreased p...

متن کامل

Noninvasive evaluation of left ventricular performance based on peak aortic blood acceleration measured with a continuous-wave Doppler velocity meter.

Peak aortic blood acceleration is recognized to be a sensitive index of global left ventricular performance. In the present study peak acceleration was assessed noninvasively in patients with a continuous-wave Doppler velocity meter. Peak aortic blood velocity and peak blood acceleration were measured by placing the ultrasonic transducer at the suprasternal notch. Measurements were obtained in ...

متن کامل

Cervical carotid imaging with a continuous-wave Doppler flowmeter.

Cervical Carotid Imaging With a ContinuousWave Doppler Flowmeter • A noninvasive technique for carotid arteriography using an ultrasonic directional Doppler flowmeter to image the carotid bifurcations is described. The technique uses a position sensing arm to hold the sharply focusing probe and translates the position of arterial flow onto an image storage screen. By multiple manual sweeps acro...

متن کامل

Ultrasound-modulated optical tomography of absorbing objects buried in dense tissue-simulating turbid media.

Continuous-wave ultrasonic modulation of scattered laser light was used to image objects buried in tissue-simulating turbid media. The buried object had an absorption coefficient greater than the background turbid medium. The ultrasonic wave that was focused into the turbid media modulated the laser light that passed through the ultrasonic field. The modulated laser light that was collected by ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interface focus

دوره 1 4  شماره 

صفحات  -

تاریخ انتشار 2011