Anterior segment characteristics in normal and keratoconus eyes evaluated with a combined Scheimpflug/Placido corneal imaging device
نویسندگان
چکیده
PURPOSE To assess the anterior segment parameters of keratoconus (KC) eyes at different stages of the disease by a new Scheimpflug camera combined with Placido disk corneal topography (Sirius, CSO, Italy) in a sample of the Iranian population. METHODS A total of 225 eyes of 225 individuals comprising 41 suspect KC, 40 mild KC, 71 moderate KC, 48 severe KC and 25 normal eyes were assessed for the following parameters: corneal thickness at the apex (CTA), thinnest corneal thickness (TCT), anterior chamber depth (ACD), corneal volume (CV), corneal keratometry (K), corneal asphericity (Q), and corneal elevation in the anterior and posterior surface. Also, the Zernike coefficients for the corneal aberrations including total root mean square (RMS), RMS Coma, RMS spherical aberration (SA), RMS Astigmatism, Baiocchi Calossi Versaci front index (BCVf), and BCV back index (BCVb) were noted for all eyes. Data was analyzed using analysis of variance (ANOVA) and post hoc Bonferroni test for comparison of the means of the five groups. P-value was considered significant if it was <0.05. RESULTS The TCT, CTA and posterior corneal elevation were significantly different between all comparison groups (P < 0.05). ACD values showed inconsistent differences between groups. Mean value of CV in comparing normal eyes vs suspect KC group, normal eyes vs mild KC, and normal eyes vs moderate KC revealed statistically significant change (P < 0.05). Also, weak non-significant positive correlation was demonstrated between K and CV (r = 0.08). There were statistically significant differences in total RMS, RMS coma, BCVf, and BCVb for most groups (P < 0.05). CONCLUSION Posterior corneal elevation, corneal thickness and high order aberrations are important indices that need to be considered to diagnose different grades of keratoconus.
منابع مشابه
Repeatability of aberrometric measurements in normal and keratoconus eyes using a new Scheimpflug-Placido topographer.
PURPOSE To evaluate the repeatability of the anterior and posterior corneal wavefront aberrations using the Sirius Scheimpflug-Placido topographer in normal eyes and keratoconus eyes. SETTING Bozok University Faculty of Medicine, Yozgat, Turkey. DESIGN Evaluation of diagnostic test. METHODS In eyes of healthy subjects and eyes of keratoconus patients, 3 repeated measurements were obtained...
متن کاملScheimpflug imaging for keratoconus and ectatic disease
Scheimpflug cross-sectioning anterior segment imaging offers significant advantages over traditional placido based curvature analysis and ultrasound pachymetry. The accurate measurement of both the anterior and posterior corneal surfaces and the anterior and posterior lens allows for the creation of a three-dimensional reconstruction of the anterior segment. Changes on both the posterior cornea...
متن کاملSingle session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug + Placido device
PURPOSE To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. METHODS In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experi...
متن کاملForme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
BACKGROUND/AIMS This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection imaging technology. CASE DESCRIPTION A 45-year-old male patient, clinically diagnosed with FFKC, with highly asymmetric manifestation between hi...
متن کاملComparative Analysis of Anterior Segment Parameters in Normal and Keratoconus Eyes Generated by Scheimpflug Tomography
Purpose. To assess and compare the anterior and posterior corneal surface parameters, keratoconus indices, thickness profile data, and data from enhanced elevation maps of keratoconic and normal corneas with the Pentacam Scheimpflug corneal tomography and to determine the sensitivity and specificity of these parameters in discriminating keratoconus from normal eyes. Methods. The study included ...
متن کامل