Electrocardiographic patterns in biventricular pacing delivered by second-generation cardiac resynchronization devices

نویسندگان

  • Amirfarjam Fazelifar
  • Fatemeh Jorfi
  • Majid Haghjoo
چکیده

BACKGROUND With increasing use of cardiac resynchronization therapy (CRT), treating physicians should be familiar with different electrocardiographic (ECG) patterns of left ventricular (LV) lead and biventricular (BiV) pacing. However, there are a few publications on ECG patterns during BiV pacing. PURPOSE This study was sought to determine different ECG patterns in patients with BiV pacing. METHODS Twelve-lead ECGs during BiV pacing (right ventricular leads at apex and LV leads in one of the lateral coronary veins) were analyzed in 181 consecutive patients (121 male; mean age, 62.0 ± 13.5 years) with advanced heart failure and baseline left bundle branch block pattern after at least 6-month of uncomplicated CRT. RESULTS During BiV pacing, 65% of the patients showed a dominant R wave in V1. There was a right axis deviation in 57% in frontal plane. However, a left superior axis emerged in 34% and normal frontal plane axis in 9%. Sequential BiV pacing (73% vs. 58%, P = 0.04) and pacing from posterolateral coronary vein (80% vs. 60%, p = 0.045) were more likely to present with a dominant R wave in V1. In sequential pacing, AV interval was significantly longer in patients with negative complex in V1 than in those with positive complex (124 ± 21 vs. 116 ± 8.0, p = 0.005). A Q/q wave was detected in 85% of patients in lead I and 78% in lead aVL. CONCLUSIONS BiV pacing from lateral coronary venous branches and right ventricular apex characteristically presented with dominant R wave in V1, Q/q wave in leads I and aVL, and right or left superior axis. However, a negative complex in V1, QRS axis in other quadrants, and lack of Q/q wave in leads I and aVL did not necessarily indicate a problem.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loss of continuous biventricular pacing in cardiac resynchronization therapy patients: incidence, causes, and outcomes.

INTRODUCTION AND OBJECTIVES In recent years, implantation of cardiac resynchronization therapy devices has significantly increased. The benefits of this therapy are directly related to the maintenance of continuous biventricular pacing. This study analyzed the incidence, causes, and outcomes of loss of continuous biventricular pacing, and the approach adopted. METHODS We analyzed the clinical...

متن کامل

lectrocardiographic imaging of cardiac resynchronization herapy in heart failure: Observation of variable lectrophysiologic responses

BACKGROUND Cardiac resynchronization therapy (CRT) for congestive heart failure patients with delayed left ventricular (LV) conduction is clinically beneficial in approximately 70% of patients. Unresolved issues include patient selection, lead placement, and efficacy of LV pacing alone. Being an electrical approach, detailed electrical information during CRT is critical to resolving these issue...

متن کامل

A comparison of cardiac resynchronization by sequential biventricular pacing and left ventricular pacing to simultaneous biventricular pacing: rationale and design of the DECREASE-HF clinical trial.

BACKGROUND The first generation of cardiac resynchronization therapy (CRT) devices approved for the treatment of heart failure used simultaneous biventricular (BiV) pacing to achieve ventricular resynchronization. Left ventricular pacing alone and sequential BiV pacing also show promise as alternative ways to deliver CRT, but have not been studied together in a large randomized trial. METHODS...

متن کامل

Use of a novel pacing mode to achieve biventricular pacing in a patient with recurrent atrial lead dislodgement after CRT-D implantation

Cardiac resynchronization therapy device (CRT-P and CRT-D) implantation has increased tremendously with increasing operator experience, eligible patients and expansion of indications. Refinements in devices and algorithms now aid physicians to improve biventricular pacing and optimize CRT. We report a case in which an interesting device program was used to achieve biventricular pacing after rep...

متن کامل

Dispersion of repolarization in cardiac resynchronization therapy.

BACKGROUND Proarrhythmic effects of cardiac resynchronization therapy (CRT) as a result of increased transmural dispersion of repolarization (TDR) induced by left ventricular (LV) epicardial pacing in a subset of vulnerable patients have been reported. The possibility of identifying these patients by ECG repolarization indices has been suggested. OBJECTIVES The purpose of this study was to te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2018