Receiver operating characteristic plots to evaluate Guthrie, Wallac, and Isolab phenylalanine kit performance for newborn phenylketonuria screening.

نویسندگان

  • S T Wang
  • S Pizzolato
  • H P Demshar
چکیده

We used ROC plots to evaluate the clinical performance of the Guthrie, Wallac, and Isolab assays for newborn phenylketonuria (PKU) screening and assessed the screening discriminatory power of these three assays by the area under the ROC plot, Youden's J index, and the likelihood ratio. The use of these plots not only allows us to pinpoint the exact cutoff value in screening, but also provides a direct comparison of these three different assays in clinical outcome performance. The optimum cutoff for the newborn PKU screening is a blood phenylalanine concentration of 0.30, 0.27, and 0.18 mmol/L for the Guthrie, Wallac, and Isolab assays, respectively. We conclude that the Wallac and Isolab kits, like the Guthrie assay, are suitable for newborn PKU screening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening for Phenylketonuria

Newborn screening for phenylketonuria (PKU) started with Robert Guthrie (1916–1995) who developed the bacterial inhibition test for the semiquantitative analysis of phenylalanine, which was the first test suitable for high throughput analysis. In addition, he introduced the ‘Guthrie filter card’ as a transport medium for dried blood which is still used today. Realizing the potential of his appr...

متن کامل

Screening for Phenylketonuria

Newborn screening for phenylketonuria (PKU) started with Robert Guthrie (1916–1995) who developed the bacterial inhibition test for the semiquantitative analysis of phenylalanine, which was the first test suitable for high throughput analysis. In addition, he introduced the ‘Guthrie filter card’ as a transport medium for dried blood which is still used today. Realizing the potential of his appr...

متن کامل

Screening for biopterin defects in newborns with phenylketonuria and other hyperphenylalaninemias.

The newborn screening for phenylketonuria (PKU) has become a common practice in many countries. The success of this type of mass screening is the result of the reliability of the Guthrie test in the identification of high blood phenylalanine levels. Recently, new syndromes other than PKU have been recognized that give high blood phenylalanine levels. These syndromes are referred to as “atypical...

متن کامل

The National Institute of Child Health and Human Development and phenylketonuria.

The National Institute of Child Health and Human Development (NICHD) was established shortly after the Guthrie test for screening newborn infants for phenylketonuria (PKU) was introduced. The NICHD supported the study demonstrating the long-term efficacy of screening and a low-phenylalanine diet in preventing mental retardation. With the identification of the adverse impact on fetal development...

متن کامل

Phenylketonuria screening with a fluorometric microplate assay.

A fluorometric assay in microtitre plates for the screening of phenylketonuria was evaluated and adapted to a neonatal screening programme. Using this assay, it is possible to determine quantitatively the phenylalanine concentration in dried blood spots on filter paper. The test exhibited a linear calibration curve with a good slope as well as sufficient precision and accuracy in the statistica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 43 10  شماره 

صفحات  -

تاریخ انتشار 1997