The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk.

نویسندگان

  • T A Kuiken
  • M M Lowery
  • N S Stoykov
چکیده

The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk was studied using finite element (FE) models of electromyogram (EMG) signal propagation. A FE model of the upper arm consisted of skin, fat, muscle and bone tissues in concentric layers. Single muscle fibre action potentials were simulated for muscle fibres at a variety of depths and combined to simulate surface EMG interference patterns. As fat layers of 3, 9 and 18 mm were added to the model, the RMS (root mean square) amplitude of the surface EMG signal directly above the centre of the active muscle decreased by 31.3, 80.2 and 90.0%, respectively. Similarly, surface EMG cross-talk above the region of inactive muscle increased as the fat layer thickness increased. The surface EMG RMS amplitude fell below 5% of its value above the centre of the muscle at 14 degrees, 17 degrees, 34 degrees and 47 degrees from the edge of the active muscle with fat layers of 0, 3, 9 and 18 mm, respectively. An additional model was developed with the subcutaneous fat layer thinned from 9 mm to 3 mm in a small, focal region under a pair of recording electrodes. Reducing the fat layer in this manner caused the surface EMG amplitude at the electrodes to increase by 241% and decreased the EMG cross-talk by 68%; this was near the values for the 3 mm uniform fat layer. This demonstrates that fat reduction surgery can increase surface EMG signal amplitude and signal independence for improved prosthesis control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simulation study to examine the use of cross-correlation as an estimate of surface EMG cross talk.

Cross-correlation between surface electromyogram (EMG) signals is commonly used as a means of quantifying EMG cross talk during voluntary activation. To examine the reliability of this method, the relationship between cross talk and the cross-correlation between surface EMG signals was examined by using model simulation. The simulation results illustrate an increase in cross talk with increasin...

متن کامل

Surface myoelectric signal cross-talk among muscles of the leg.

Surface myoelectric signals were detected from the skin surface above the tibialis anterior muscle, the peroneus brevis muscle, the soleus muscle and the tibial bone during selective maximal electrical stimulation of the tibialis anterior muscle in 12 normal subjects. The double differential technique developed by Broman et al. (1985) was used to determine if the detected signal was due to volu...

متن کامل

THE EFFECT OF 12 WEEKS OF MODERATE INTENSITY CONTINUOUS TRAINING (MICT) ON INFLAMMATORY AND ANGIOGENESIS FACTORS OF VISCERAL AND SUBCUTANEOUS ADIPOSE TISSUE IN OBESE RATS: A SEMI-EXPERIMENTAL STUDY

Background & Aims: Physical activity by modulating angiogenesis in adipose tissue, effects on the entire body metabolic profile. Therefore, the aim of this study was to investigate the effect of 12 weeks of moderate intensity continuous training on VEGF, PEDF and PAI-1 of visceral and subcutaneous adipose tissue in obese rats. Materials & Methods: 15 male Wistar rats were divided into 2 groups...

متن کامل

The Effect of 6 Weeks Aerobic Training and Aqueous Extract of Caraway Seed (Carum Carvi) on the Expression of CTRP12 Gene, Body Weight Changes and Subcutaneous Adipose Tissue in Obese Male Rats: An Experimental Study

Background and Objectives: Caraway (Carum carvi) is one of the medicinal plants which is traditionally used for weight loss. The purpose of the present study was to determine the effect of 6 weeks aerobic training and aqueous extract of caraway seed (carum carvi) on expression of CTRP12 gene, body weight changes and subcutaneous adipose tissue in obese male rats. Materials and Methods: In this...

متن کامل

Electrically evoked myoelectric signals.

Electrical stimulation of the nervous system is attracting increasing attention because of the possibilities it offers for physiological investigations, clinical diagnosis, muscle function assessment, noninvasive muscle characterization, and functional control of paralyzed extremities. Parameters of the myoelectric signal evoked by surface stimulation of a muscle motor point or by stimulation o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 2003