Evaluation of Exerting Force on the Heating Surface Due to Bubble Ebullition in Subcooled Flow Boiling

نویسنده

  • M. R. Nematollahi
چکیده

Vibration characteristics of subcooled flow boiling on thin and long structures such as a heating rod were recently investigated by the author. The results show that the intensity of the subcooled boiling-induced vibration (SBIV) was influenced strongly by the conditions of the subcooling temperature, linear power density and flow velocity. Implosive bubble formation and collapse are the main nature of subcooled boiling, and their behaviors are the only sources to originate from SBIV. Therefore, in order to explain the phenomenon of SBIV, it is essential to obtain reliable information about bubble behavior in subcooled boiling conditions. This was investigated at different conditions of coolant subcooling temperatures of 25 to 75°C, coolant flow velocities of 0.16 to 0.53m/s, and linear power densities of 100 to 600 W/cm. High speed photography at 13,500 frames per second was performed at these conditions. The results show that even at the highest subcooling condition, the absolute majority of bubbles collapse very close to the surface after detaching from the heating surface. Based on these observations, a simple model of surface tension and momentum change is introduced to offer a rough quantitative estimate of the force exerted on the heating surface during the bubble ebullition. The formation of a typical bubble in subcooled boiling is predicted to exert an excitation force in the order of 10 N. Keywords—Subcooled boiling, vibration mechanism, bubble behavior.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Heat Transfer Shear of Different Mechanisms in Subcooled Nucleate Boiling

Since the mean characteristic of nucleate boiling is bubble formation and collapse near the heating surface, in this study attempts have been made to investigate heat transfer effects due to the bubbles ebullition and collapse cycle. All possible heat transfer mechanisms are studied qualitatively and quantitatively. For quantitative calculation of the heat transfer portion by each of the introd...

متن کامل

Modeling of Upward Subcooled Flow Boiling of Refrigerant-113 in a Vertical Annulus

In this paper, a modified two-fluid model has been adopted to simulate the process of upward vertical subcooled flow boiling of refrigerant R-113 in a vertical annular channel at low pressure. The modified model considers temperature dependent properties and saturation temperature variation and was validated against a number of published low-pressure subcooled boiling experiments. The results s...

متن کامل

Simulation of Subcooled Flow Boiling Occurring in Internal Combustion Engine Water Jacket by Numerical Modeling in a Channel with Hot Spot

Boiling heat transfer always has been proposed as a solution for enhancing heat transfer between the fluid and solid surfaces. Subcooled flow boiling is one of the mechanisms that occur in Internal Combustion Engine water jacket in which high amounts of heat is transferred. In this research, it has been tried to simulate subcooled flow boiling in a geometry similar to coolant channel inside the...

متن کامل

Development of a Numerical Model for Subcooled Boiling Flow

Population balance equations combined with a threedimensional two-fluid model are employed to predict bubbly flows with the presence of heat and mass transfer processes. Subcooled boiling flow belongs to this specific category of bubbly flows is considered. The MUSIG (MUltiple-SIze-Group) model implemented in CFX4.4 is further developed to account for the wall nucleation and condensation in the...

متن کامل

Experimental Study on the Effect of Magnetic Field on Critical Heat Flux of Ferrofluid Flow Boiling in a Vertical Tube

In the present work, the critical heat flux measurements were performed for the subcooled flow boiling of pure water and magnetic nanofluids (i.e., water + 0.01 and 0.1 vol.% Fe‌‌3O4) in a vertical tube. The effect of applying an external magnetic field on the CHF variation was studied experimentally as well. The obtained results indicated that the subcooled flow boiling CHF in the vertical tub...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009