[Relationship between plasma C-reactive protein level and neointimal hyperplasia volume in patients with zotarolimus-eluting stents. Volumetric analysis by three-dimensional intracoronary ultrasound].

نویسندگان

  • Leandro I Lasave
  • Alexandre A C Abizaid
  • Julio Paiva e Maia
  • José de Ribamar Costa
  • Fausto Feres
  • Luiz A Mattos
  • Andrea S Abizaid
  • Dimytri A Siqueira
  • Luiz F Tanajura
  • Rodolfo Staico
  • Pedro Beraldo de Andrade
  • Sérgio N Braga
  • Amanda G M R Sousa
  • J Eduardo Sousa
چکیده

INTRODUCTION AND OBJECTIVES C-reactive protein (CRP) is an inflammatory marker that predicts cardiac events in patients with coronary syndromes. However, data on the relationship between the CRP level and in-stent restenosis are contradictory. The objective of this study was to investigate the relationship between the basal CRP level and the neointimal hyperplasia volume measured by intracoronary ultrasound 4 months after implantation of a zotarolimus-eluting stent. METHODS The study included 40 consecutive patients who underwent zotarolimus-eluting stent implantation. Patients were divided into quartiles according to their preprocedural CRP level. Intracoronary ultrasound was performed after stent implantation and at 4 months, and the neointimal hyperplasia volume was determined using Simpson's rule. Correlation and linear regression analyses were used to evaluate the relationships between variables. Multivariate analysis was used to identify variables that were independently related to neointimal hyperplasia volume. RESULTS The patients' mean age was 58 (8) years, 55% were male, and 40% had diabetes mellitus. There was no difference in baseline characteristics between the quartiles. The hyperplasia volumes were 4.8 (4.2) microl and 15.8 (10.0) microl in the first and fourth quartiles, respectively (P< .001). There was a significant positive correlation between the CRP level and neointimal hyperplasia volume (r = 0.64, P=.0001). The CRP level, the postimplantation lumen volume, and the final deployment pressure were all independent predictors of neointimal hyperplasia. CONCLUSIONS In this study, an independent correlation was observed between the CRP level before zotarolimus-eluting stent implantation and the neointimal hyperplasia volume at 4-month follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of zotarolimus-eluting stents with sirolimus-eluting and paclitaxel-eluting stents: intimal hyperplasia and vascular changes assessed by volumetric intravascular ultrasound analysis.

BACKGROUND As a substudy of the large, randomized ZEST (Comparison of the Efficacy and Safety of Zotarolimus-Eluting Stent with Sirolimus-Eluting and PacliTaxel-Eluting Stent for Coronary Lesions) trial comparing first- and second-generation drug-eluting stents, we evaluated intimal hyperplasia (IH) and vascular changes using volumetric intravascular ultrasound analysis. METHODS AND RESULTS C...

متن کامل

Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers

Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from t...

متن کامل

Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from...

متن کامل

Impact of diabetes mellitus on vessel response in the drug-eluting stent era: pooled volumetric intravascular ultrasound analyses.

BACKGROUND Exaggerated neointimal hyperplasia is considered as the primary mechanism for increased restenosis in patients with diabetes mellitus (DM) treated with bare-metal stent. However, the vessel response in DM and non-DM treated with different drug-eluting stents (DES) has not been systematically evaluated. METHODS AND RESULTS We investigated 3D intravascular ultrasound (postprocedure a...

متن کامل

Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up.

BACKGROUND We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. METHODS AND RESULTS Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 60 9  شماره 

صفحات  -

تاریخ انتشار 2007