Numerical Comparison Between TEM Head Coil and Birdcage Head Coil at 7T
نویسندگان
چکیده
G. D. DeMeester, Z. Zhai, M. A. Morich, C. Leussler, C. Findeklee Philips Medical Systems, Cleveland, Ohio, United States, Philips Research Laboratories, Hamburg, Hamburg, Germany Introduction A TEM T/R head coil and a shielded birdcage T/R head coil operated at 298MHz/7T were both modeled using the Finite Difference Time Domain (FDTD) method. The two coils have approximately the same physical size. B1-field and SAR were calculated for the two head coils loaded with a realistic human head model. B1-field comparison shows a slightly better B1-field uniformity inside the head for the birdcage coil design. SAR comparison shows, that for the same average B1-field strength over the center slice of the head, the birdcage head coil gives lower head and local SAR. Methods Two kinds of T/R head coils for use at 7T were designed. The first one was a head coil based on TEM theory [1]. It has a copper cavity shell with the diameter of 35cm and the length of 18cm. Two copper end plates are connected to the cavity shell at the front and back. The back end plate is a closed cap with slots, and the front end plate is open with a 28cm-diamter patient aperture. There are 16 tunable coil elements located at a diameter of 30cm within the cavity shell. The second head coil was a shielded bandpass birdcage [2]. The geometry of the birdcage is based on that of the TEM coil. The front end plate of the TEM coil was removed and replaced with a 1cm-wide copper strip for the birdcage end ring. Gaps were opened in the end ring and ring capacitors with the value of 10pF were inserted. The 16 elements of the TEM coil were used as the birdcage rungs with distributed capacitors. To reduce the peak E-field along the coil rungs, one additional capacitor was placed in the middle of each rung. An RF shield was included for the birdcage coil at diameter of 35cm. For better shield effect, the length of the RF shield was extended 3cm longer in the front past the end-ring. The closed end cap, which is connected to the RF shield, was also included in the birdcage coil. The two coils have about the same physical size. In Fig. 1, we show the equivalent circuits of the two head coils. XFDTD software package (Remcom, Inc., State College, PA) was used to model the two coils with 2mm isotropic resolution [3]. Copper was modeled as a conductor with conductivity σ = 5.8×10 S/m. Capacitors were modeled by assigning passive loads in the gaps opened at their locations. A 2mm resolution human head model with portions of the shoulders was generated from the raw data of a segmented human body model obtained from [4]. Head tissue conductivities and relative permittivities were assigned at the frequency of 298MHz using [4]. The head model was placed in the TEM and birdcage head coils. Both head coil models were tuned to 298MHz and driven in quadrature by four 50Ω-sources near the end cap. Steady-state solutions were obtained. B1 -field in the rotating frame was then calculated using the formula in [5]. Head SAR and local SAR were also calculated with respect to a constant average B1 -field strength over the central slice the transverse slice at the isocenter of two head coils. Results In Fig. 2(a), we plot the normalized |B1 |-field with respect to the field at the isocenter along the z-axis for the unloaded TEM and birdcage head coils. It shows that, the TEM coil curve has a higher B1 -field near the end cap that monotonically decreases toward the front of the coil. The birdcage coil B1 -field curve is relatively flat near the end cap and decreases similarly to the TEM curve toward the front of the coil. In this comparison, the birdcage has better B1 -field homogeneity along the zaxis than that of the TEM coil. With the loading of a human head model, we found, that the B1 -field inside the head is dramatically deviated from the unloaded field by the dielectric head tissues and eddy current effects. In Fig. 2(b), we plot the normalized average B1 -field per slice with respect to the central slice vs. z-axis. In this case, the two curves show a similar trend but with slightly better B1 -field uniformity in the brain for the birdcage coil. In Fig. 2 (c), we also plot the corresponding B1 field standard deviation per slice vs. z-axis. It shows that, B1 -field homogeneity within a slice generally improves as one moves from the neck to the brain. In the brain slices, B1 -field standard deviation is below 11% for both head coils. In Table 1, we listed the calculated head SAR and maximum local SAR for the two head coil configurations. For purposes of comparison, the RF duty cycle is fixed at 2.4% and the average B1 -field field strength is 10μT over the central slice. It shows, that the IEC’s local SAR limit (≤10W/kg) is reached first in the head for the TEM coil. Head SAR is also higher for the TEM coil. For the same average B1 -field strength, the birdcage coil has ~29% lower head SAR and ~27% lower local SAR compared to the TEM head coil. Conclusions Our numerical simulations for two T/R head coil designs at 7T show that birdcage coils are still applicable at ultra-high fields. The birdcage head coil can have comparable or better B1 -field uniformity along the z-axis in the head than a similarly sized TEM head coil. TEM head coil and birdcage head coil have somewhat similar B1 -field inhomogeneity due to the dominant head tissue effects. The birdcage head coil seems to benefit from lower SAR than a similarly sized TEM head coil. References [1]. J. Thomas Vaughan, et. al., MRM 32:206-218 (1994); Brian A. Baetlein, et. al, IEEE Trans. Biomed. Eng. 47:535-546 (2000). [2]. C. E. Hayes, et. al, J. Magn. Reson. 63: 622-628(1985); J. Tropp, J. Magn. Reson. 82: 51-62 (1989). [3]. Christopher M. Collins, et. al, MRM 40:847-856 (1998); T. S. Ibrahim, et. al, Magn. Reson. Imag. 18: 835-843 (2000). [4]. US Air Force Research Laboratory, http://www.brooks.af.mil/AFRL/HED/hedr/; Camelia Gabriel, Brooks Air Force Base, report no. AL/OE-TR-1996-0037. [5]. D. I. Hoult, Concepts Magn. Reson. 12(4): 173-187 (2000).
منابع مشابه
Towards the Optimum 7T Head RF Coil
G. McKinnon, E. Boskamp GE Medical Systems, Waukesha, WI, United States Introduction Numerical simulations were used in an attempt to find the optimal configuration for a 7T head coil. The high-pass birdcage, the hybrid birdcage, and the TEM resonator were compared. The coil dimensions were kept as similar as possible. Performance was evaluated on the basis of normalized peak E field, SNR and B...
متن کاملSAR and B1 Field in a Human Head Model for Birdcage, TEM and Microstrip Coils at 7T
Introduction: The advantage of high field MRI is high SNR which can increase image resolution or decrease acquisition time. However, there are some challenges, such as the RF wavelength effect and the power deposition in tissues. A comparison of three different volume coils loaded with the same spherical homogeneous phantom has been reported [1]. In order to mimic the B1 field distribution and ...
متن کاملA 7T 8 channel transmit-receive dipole array for head imaging: dipole element and coil evaluation
Target audience: Radiofrequency (RF) engineers, anyone interested in high field RF coils, parallel transmit or high field brain imaging. Introduction: Electric dipole antennas are seeing increasing use for 7T MR imaging. They differ from conventional surface coil loops in many ways. With 8 elements surrounding a body sized tissue equivalent phantom and array of dipole antennas can achieve highe...
متن کاملDouble Tuned 31P/1H Elliptical Transceiver Phased Array for the Human Brain Studies at 7 T
Introduction: The improved SNR at 7T provides significant advantages for both H and lower gyromagnetic nuclei such as P, Na and C (X nuclei). Double resonant volume head coils, based on both birdcage (1-3) and TEM (4) designs have been previously used at lower magnetic fields. However at 7T, transceiver phased arrays provide significant advantages for both B1 homogeneity and transmit efficiency...
متن کاملImproved B1+ field using a 16-channel Transmit Head Array and an 8-channel pTx System at 7T
INTRODUCTION At 7T, transmit coil arrays using parallel transmit (pTx) [1] systems enable techniques to substantially improve B1 transmit fields. Receive coil arrays offer enhanced sensitivity and parallel imaging performance. However, significant challenges in ultra high field systems are still remaining for the design and implementation of RFcoils for dedicated transmit channels and their int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002