Use of microdosing and accelerator mass spectrometry to evaluate the pharmacokinetic linearity of a novel tricyclic GyrB/ParE inhibitor in rats.
نویسندگان
چکیده
Determining the pharmacokinetics (PKs) of drug candidates is essential for understanding their biological fate. The ability to obtain human PK information early in the drug development process can help determine if future development is warranted. Microdosing was developed to assess human PKs, at ultra-low doses, early in the drug development process. Microdosing has also been used in animals to confirm PK linearity across subpharmacological and pharmacological dose ranges. The current study assessed the PKs of a novel antimicrobial preclinical drug candidate (GP-4) in rats as a step toward human microdosing studies. Dose proportionality was determined at 3 proposed therapeutic doses (3, 10, and 30 mg/kg of body weight), and PK linearity between a microdose and a pharmacological dose was assessed in Sprague-Dawley rats. Plasma PKs over the 3 pharmacological doses were proportional. Over the 10-fold dose range, the maximum concentration in plasma and area under the curve (AUC) increased 9.5- and 15.8-fold, respectively. PKs from rats dosed with a (14)C-labeled microdose versus a (14)C-labeled pharmacological dose displayed dose linearity. In the animals receiving a microdose and the therapeutically dosed animals, the AUCs from time zero to infinity were 2.6 ng · h/ml and 1,336 ng · h/ml, respectively, and the terminal half-lives were 5.6 h and 1.4 h, respectively. When the AUC values were normalized to a dose of 1.0 mg/kg, the AUC values were 277.5 ng · h/ml for the microdose and 418.2 ng · h/ml for the pharmacological dose. This 1.5-fold difference in AUC following a 300-fold difference in dose is considered linear across the dose range. On the basis of the results, the PKs from the microdosed animals were considered to be predictive of the PKs from the therapeutically dosed animals.
منابع مشابه
Evaluation of microdosing to assess pharmacokinetic linearity in rats using liquid chromatography-tandem mass spectrometry.
The microdosing strategy allows for early assessment of human pharmacokinetics of new chemical entities using more limited safety assessment requirements than those requisite for a conventional phase I program. The current choice for evaluating microdosing is accelerator mass spectrometry (AMS) due to its ultrasensitivity for detecting radiotracers. However, the AMS technique is still expensive...
متن کاملUnexplored pharmacokinetic opportunities with microdosing in oncology.
The publication of the U.S. Food and Drug Administration’s ‘‘Critical Path’’ document highlights the importance of translational research and the development of new concepts and tools that may help provide more confidence in the selection of drug candidates early in clinical development. One type of exploratory study, the so-called phase 0 trial, allows dosing to pharmacologic response and limi...
متن کاملApproaches using molecular imaging technology -- use of PET in clinical microdose studies.
Positron emission tomography (PET) imaging uses minute amounts of radiolabeled drug tracers and thereby meets the criteria for clinical microdose studies. The advantage of PET, when compared to other analytical methods used in microdose studies, is that the pharmacokinetics (PK) of a drug can be determined in the tissue targeted for drug treatment. PET microdosing already offers interesting app...
متن کاملPhysicochemical, Stress Degradation Evaluation and Pharmacokinetic Study of AZGH101; a New Synthesized COX2 Inhibitor after I.V. and Oral Administration in Male and Female Rats
Nonsteroidal anti-inflammatory drugs (NSAIDs) act mainly via inhibition of prostaglandins synthesis by inhibition of cyclooxygenase (COX) isoenzymes (COX1 and COX 2). Selective COX-2 inhibitors which are also known as coxibs provide the main therapeutic effects of NSAIDs. Zarghi et al. reported 6-benzoyl-2-(4-(methylsulfonyl)phenyl)quinoline-4-carboxylic acid (AZGH 101) as a novel derivative of...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 58 11 شماره
صفحات -
تاریخ انتشار 2014