Transorbital Penetrating Brain Injury with a Large Foreign Body

نویسندگان

  • Arti Singh
  • Shashi Kumar Bhasker
  • Balvant Kumar Singh
چکیده

A 30-year-old man presented with forward protrusion of the left globe one hour after falling in a ditch of wooden sticks. Except for a minor headache, no other neurological abnormality was reported. The patient was well oriented in time, place and person without any neurological deficit. Glasgow coma scale (GCS) score was 15 and all vital signs were within normal limits. Ophthalmic examination revealed visual acuity of no light perception in the left eye while the left globe was proptotic and displaced temporally. Movements of the left eye were restricted in all directions and eyelid closure was inadequate. A 1.5 cm laceration was present in the medial part of the left upper eyelid, yet no foreign body was detected. Upon presentation, the left ocular surface was covered with blood clots which disclosed conjunctival congestion and chemosis after cleaning. The left pupil and fundus were not visible because of hyphema and consensual light reflex was absent in the right eye (Fig. 1). Ocular examination was normal in the fellow eye. A diagnosis of post-traumatic retrobulbar hemorrhage was made based on the clinical presentation, and orbital and cranial CT scans were requested accordingly. CT scan demonstrated an elongated, well-defined and extremely low-attenuation area within a thin rim of high density in the medial aspect of the left orbit, passing through the superior orbital fissure into the ipsilateral temporal lobe lateral to the sellar region and almost juxtaposing the brainstem posteriorly. The above-mentioned features were suggestive of an orbitocranial foreign body which appeared to be a bamboo stick measuring 11x0.8 cm. A bone fragment was noted at the superior orbital fissure which was consistent with fracture of the greater sphenoid wing. Moreover, intracerebral hemorrhage was present in the left temporal lobe (Fig. 2). With a diagnosis of orbitocranial penetrating injury through the superior orbital fissure the patient was further observed and followed by neurosurgeons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transorbital Penetrating Intracranial Injury Caused by Sheppard’s Hook

Intracranial injury resulting from transorbital penetrating objects is rare in a noncombat setting. As such there is a significant lack of data pertaining to the management of non-projectile traumatic brain injuries due to foreign bodies entering the brain. Intracranial complications can include intracerebral hematoma, cerebral contusion, intraventricular hemorrhage, pneumocephalus, brain stem ...

متن کامل

Occult Orbitocranial Penetrating Pencil Injury in a Child

Transorbital slow-penetrating injury is an uncommon type of head injury that is seen more often in the pediatric age group. This type of injury can be occult, which is often associated with serious complications. We report on a 4-year-old female who presented with orbital swelling after an unwitnessed right orbital injury following a fall on her face at her school. Three days after injury, the ...

متن کامل

Transorbital Penetrating Intracranial Injury by a Chopstick

A 38-year-old man fell from a chair with a chopstick in his hand. The chopstick penetrated his left eye. He noticed pain, swelling, and numbness around his left eye. On physical examination, a linear wound was noted at the medial aspect of the left eyelid. Noncontrast computed tomography (CT) study showed a linear hypodense structure extending from the medial aspect of the left orbit to the occ...

متن کامل

Transorbital globe sparing penetrating cranial injury with a metallic screw: large cranio-orbital foreign body.

Gaur N, et al. BMJ Case Rep 2017. doi:10.1136/bcr-2017-221248 Description A 14-year-old man presented to the emergency services following trauma to his left eye (LE) sustained during a battery explosion. The patient was conscious, and oriented in time, space and person, and higher mental functions were preserved. The patient had visual acuity of light perception in his left eye. Head of a metal...

متن کامل

Penetrating brain injury caused by retained plastic tip of ballpoint pen.

Radiological evaluation was performed using a 64MDCT scanner without any sedation. Multiplanar reformation images clearly revealed a residual foreign body – possibly the tip of the ballpoint pen – in the frontal lobe ( fig. 1 ). Therefore, surgical removal of the foreign body was planned. Bifrontal craniotomy was performed. The orbital roof was found to be fractured, and bone fragments were lod...

متن کامل

An unusual transorbital penetrating injury and principles of management.

The objective of this study was to present an unusual low velocity transorbital penetrating injury. The study design was a clinical record (case report). A 38-year-old gentleman tripped and fell face first onto the wing of an ornamental brass eagle. This penetrated the inferomedial aspect of the right orbit, breaching the lamina papyracea to extend into the ethmoid sinuses and reaching the dura...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013