Blood transfusions increase circulating plasma free hemoglobin levels and plasma nitric oxide consumption: a prospective observational pilot study

نویسندگان

  • Iris C Vermeulen Windsant
  • Norbert CJ de Wit
  • Jonas TC Sertorio
  • Erik AM Beckers
  • Jose E Tanus-Santos
  • Michael J Jacobs
  • Wim A Buurman
چکیده

INTRODUCTION The increasing number of reports on the relation between transfusion of stored red blood cells (RBCs) and adverse patient outcome has sparked an intense debate on the benefits and risks of blood transfusions. Meanwhile, the pathophysiological mechanisms underlying this postulated relation remain unclear. The development of hemolysis during storage might contribute to this mechanism by release of free hemoglobin (fHb), a potent nitric oxide (NO) scavenger, which may impair vasodilation and microcirculatory perfusion after transfusion. The objective of this prospective observational pilot study was to establish whether RBC transfusion results in increased circulating fHb levels and plasma NO consumption. In addition, the relation between increased fHb values and circulating haptoglobin, its natural scavenger, was studied. METHODS Thirty patients electively received 1 stored packed RBC unit (n = 8) or 2 stored packed RBC units (n = 22). Blood samples were drawn to analyze plasma levels of fHb, haptoglobin, and NO consumption prior to transfusion, and 15, 30, 60 and 120 minutes and 24 hours after transfusion. Differences were compared using Pearson's chi-square test or Fisher's exact test for dichotomous variables, or an independent-sample t test or Mann-Whitney U test for continuous data. Continuous, multiple-timepoint data were analyzed using repeated one-way analysis of variance or the Kruskall-Wallis test. Correlations were analyzed using Spearman or Pearson correlation. RESULTS Storage duration correlated significantly with fHb concentrations and NO consumption within the storage medium (r = 0.51, P < 0.001 and r = 0.62, P = 0.002). fHb also significantly correlated with NO consumption directly (r = 0.61, P = 0.002). Transfusion of 2 RBC units significantly increased circulating fHb and NO consumption in the recipient (P < 0.001 and P < 0.05, respectively), in contrast to transfusion of 1 stored RBC unit. Storage duration of the blood products did not correlate with changes in fHb and NO consumption in the recipient. In contrast, pre-transfusion recipient plasma haptoglobin levels inversely influenced post-transfusion fHb concentrations. CONCLUSION These data suggest that RBC transfusion can significantly increase post-transfusion plasma fHb levels and plasma NO consumption in the recipient. This finding may contribute to the potential pathophysiological mechanism underlying the much-discussed adverse relation between blood transfusions and patient outcome. This observation may be of particular importance for patients with substantial transfusion requirements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF SIX WEEKS OF ENDURANCE TRAINING WITH LEMON CONSUMPTION ON PLASMA LEVELS OF ENDOTHELIN-1 AND NITRIC OXIDE IN STREPTOZOTOCIN-INDUCED DIABETIC RATS

Background: The purpose of this study was to evaluate the effect of six weeks of endurance training with sour lemon consumption on plasma levels of endolin-1 and nitric oxide in streptozotocin-induced diabetic rats. Methods: In this experimental study, 72 male Wistar rats (Weight; 200 ± 12 g) were selected and randomly divided into eight groups after becoming diabetic. Endurance training proto...

متن کامل

P-79: The Correlation between Nitric Oxide Levels in Seminal Plasma with Human Sperm Parameters

Background: Defective sperm quality is a significant cause of infertility in men. It is known that nitric oxide (NO) is a highly reactive free radical gas which has a dual function, being both a cytotoxic and necessary molecule for normal sperm production. Materials and Methods: To investigate correlation between NO levels with sperm parameters, a case-control study were designed with total of ...

متن کامل

Hemolysis-Associated Nitric Oxide Dysregulation during Extracorporeal Membrane Oxygenation.

Acute intravascular hemolysis during extracorporeal membrane oxygenation (ECMO) leads to increased levels of cell-free hemoglobin (FHb). Our aim was to investigate whether FHb levels are associated with nitric oxide (NO) consumption and clinical outcomes. A prospective observational study was performed involving pediatric patients on ECMO. Blood samples were collected before, during, and after ...

متن کامل

Plasma Free Hemoglobin and Microcirculatory Response to Fresh or Old Blood Transfusions in Sepsis

BACKGROUND Free hemoglobin (fHb) may induce vasoconstriction by scavenging nitric oxide. It may increase in older blood units due to storage lesions. This study evaluated whether old red blood cell transfusion increases plasma fHb in sepsis and how the microvascular response may be affected. METHODS This is a secondary analysis of a randomized study. Twenty adult septic patients received eith...

متن کامل

The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin: a novel mechanism of human disease.

CONTEXT The efficient sequestration of hemoglobin by the red blood cell membrane and the presence of multiple hemoglobin clearance mechanisms suggest a critical need to prevent the buildup of this molecule in the plasma. A growing list of clinical manifestations attributed to hemoglobin release in a variety of acquired and iatrogenic hemolytic disorders suggests that hemolysis and hemoglobinemi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2012