Assessment of aortic valve area combining echocardiography and magnetic resonance imaging.
نویسندگان
چکیده
BACKGROUND Transthoracic echocardiography (TTE) is routinely used to calculate aortic valve area (AVA) by continuity equation (CE). However, accurate measurement of the left ventricular outflow tract (LVOT) can be difficult and flow acceleration in the LVOT may lead to miscalculation of the AVA. OBJECTIVE The aim of our study was to compare AVA measurements by standard TTE, cardiac magnetic resonance imaging (MRI) and a hybrid approach combining both techniques. METHODS AVA was calculated in 38 patients (age 73±9 years) with standard TTE, cine-MRI planimetry and a hybrid approach: Hybrid Method 1: TTE-derived LVOT measurement in the CE numerator was replaced by the MRI assessment of the LVOT and AVA was calculated: (LVOT(MRI)/*LVOT-VTI(TTE))/transaortic-VTI(TTE). Method 2: We replaced the SV in the numerator by the MRI-derived SV and calculated AVA = SV(MRI)/ transaortic-VTI(TTE). RESULTS Mean AVA derived by TTE was 0.86 cm(2)±0.23 cm(2) and 0.83 cm(2)±0.3 cm(2) by MRI- planimetry, respectively. The mean absolute difference in AVA was 0.03 cm(2) for TTE vs. MRI planimetry. AVA calculated with method 1 and method 2 was 1.23 cm(2)±0.4 cm(2) and 0.92 cm(2)±0.32 cm(2), respectively. The mean absolute difference between TTE and method 1 and method 2 was 0.37 cm(2) and 0.06 cm(2), respectively (p<0.001). CONCLUSION MRI-planimetry of AVA and hybrid method 2 are accurate and showed a good agreement with standard TTE measurements. Therefore, hybrid method 1 is a reasonable alternative if poor acoustic windows or LVOT flow accelerations limit the accuracy of TTE, particularly in patients at high risk for an invasive hemodynamic study.
منابع مشابه
3T CMR for quantification of aortic valve area - A comparison between continuity equation via phase contrast sequences and planimetric analysis
Introduction Assessment of aortic valve area (AVA) is primarily carried out by echocardiography in clinical routine. In cases of insufficient acoustic window, discrepant medical findings or suboprimal Doppler conditions, 1.5 T magnetic resonance imaging (MRI) is discussed as an noninvasive alternative imaging method for planimetry of AVA. If quantification of AVA is also possible at higher magn...
متن کاملMultiparametric Assessment of Post-Transcatheter Aortic Valve Replacement Paravalvular Regurgitation Grading by Transthoracic Echocardiography and Cardiac Magnetic Resonance
Purpose: Paravalvular regurgitation post-transcatheter valve replacement is associated with poor outcomes. The Valve Academic Research Consortium has defined qualitative and quantitative criteria for assessing paravalvular leak severity by transthoracic echocardiography. Cardiac magnetic resonance imaging is highly accurate and reproducible in measuring aortic flow volumes, and has been used fo...
متن کاملMultimodality assessment of aortic stenosis severity in Transcatheter Aortic Valve Implantation (TAVI): comparison between cardiovascular magnetic resonance, transesophageal and transthoracic echocardiography
Multimodality assessment of aortic stenosis severity in Transcatheter Aortic Valve Implantation (TAVI): comparison between cardiovascular magnetic resonance, transesophageal and transthoracic echocardiography Andrew Jabbour, Tevfik F Ismail, Ali Vazir, Isabelle Roussin, Ankur Gulati, Francisco Alpendurada, Sameer Zaman, Oluwatosin Sotubo, Saman S Zaman, Benjamin Hewins, Simon Davies, Sanjay K P...
متن کاملCardiovascular magnetic resonance assessment of the aortic valve stenosis: an in vivo and ex vivo study
BACKGROUND Aortic valve area (AVA) estimation in patients with aortic stenosis may be obtained using several methods. This study was undertaken to verify the cardiovascular magnetic resonance (CMR) planimetry of aortic stenosis by comparing the findings with invasive catheterization, transthoracic (TTE) as well as tranesophageal echocardiography (TEE) and anatomic CMR examination of autopsy spe...
متن کاملAortic Stenosis: Evaluation with Multidetector CT Angiography and MR Imaging
Aortic valvular stenosis (AS) is the most common valve disease which results in the need for a valve replacement. Although a Doppler echocardiography is the current reference imaging method, the multidetector computerized tomograpghy (MDCT) and magnetic resonance imaging (MRI) have recently emerged as a promising method for noninvasive valve imaging. In this study, we briefly describe the usefu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 98 3 شماره
صفحات -
تاریخ انتشار 2012