HPLC assay of melatonin in plasma with fluorescence detection.
نویسندگان
چکیده
We report an HPLC assay for melatonin that incorporates automated injection, methanol/water mobile phase, and fluorescence detection. Plasma samples were extracted by solid and liquid phases. Recovery was > 70% for 1-10 mL of plasma extracted, approximately 40 pg-250 ng of melatonin. Samples were dried and reconstituted in 100 mL/L methanol. Injections were 25 microL or 150 microL, depending on sample concentration, and the melatonin peak was eluted in 380 mL/L methanol. The detection limit of the assay was 6 pg on the column, allowing a practical sensitivity in plasma of 11 pmol/L for 8-mL samples and 34 pmol/L for 2-mL samples. More than 100 plasma samples from volunteers and patients were assayed and the results compared with an established RIA. The mean daytime concentration of melatonin was 20.7 pmol/L (SEM = 1.2) and 18.5 pmol/L (SEM = 1.6) for HPLC and RIA, respectively, and the mean nighttime concentration was 82.4 pmol/L (SEM = 6.5) and 82.2 (SEM = 7.3), respectively.
منابع مشابه
A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملDetermination of Ivermectin Residues in Bovine Liver Samples By ELISA and HPLC with Fluorescence Detection
ABSTRACT Background and Objectives: Ivermectin is an anti-parasitic medication frequently used in many food-producing animals. This study aimed to investigate the level of ivermectin residue in liver samples collected from slaughterhouses in Qazvin Province, Iran. Methods: Overall, 88 bovine liver sam...
متن کاملHighly sensitive and specific assay of plasma melatonin using high-performance liquid chromatography with fluorescence detection preceded by solid-phase extraction.
This paper describes a new, highly sensitive, rapid method for the determination of low levels of endogenous melatonin, the pineal and retinal hormone, in fish plasma samples. The combination of solid-phase extraction and high-performance liquid chromatography with fluorescence detection significantly improves the separation and increases the sensitivity of the assay. The proposed method may be...
متن کاملA High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma
A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 39 11 Pt 1 شماره
صفحات -
تاریخ انتشار 1993