Cardiorespiratory dynamics measured from continuous ECG monitoring improves detection of deterioration in acute care patients: A retrospective cohort study

نویسندگان

  • Travis J Moss
  • Matthew T Clark
  • James Forrest Calland
  • Kyle B Enfield
  • John D Voss
  • Douglas E Lake
  • J Randall Moorman
چکیده

BACKGROUND Charted vital signs and laboratory results represent intermittent samples of a patient's dynamic physiologic state and have been used to calculate early warning scores to identify patients at risk of clinical deterioration. We hypothesized that the addition of cardiorespiratory dynamics measured from continuous electrocardiography (ECG) monitoring to intermittently sampled data improves the predictive validity of models trained to detect clinical deterioration prior to intensive care unit (ICU) transfer or unanticipated death. METHODS AND FINDINGS We analyzed 63 patient-years of ECG data from 8,105 acute care patient admissions at a tertiary care academic medical center. We developed models to predict deterioration resulting in ICU transfer or unanticipated death within the next 24 hours using either vital signs, laboratory results, or cardiorespiratory dynamics from continuous ECG monitoring and also evaluated models using all available data sources. We calculated the predictive validity (C-statistic), the net reclassification improvement, and the probability of achieving the difference in likelihood ratio χ2 for the additional degrees of freedom. The primary outcome occurred 755 times in 586 admissions (7%). We analyzed 395 clinical deteriorations with continuous ECG data in the 24 hours prior to an event. Using only continuous ECG measures resulted in a C-statistic of 0.65, similar to models using only laboratory results and vital signs (0.63 and 0.69 respectively). Addition of continuous ECG measures to models using conventional measurements improved the C-statistic by 0.01 and 0.07; a model integrating all data sources had a C-statistic of 0.73 with categorical net reclassification improvement of 0.09 for a change of 1 decile in risk. The difference in likelihood ratio χ2 between integrated models with and without cardiorespiratory dynamics was 2158 (p value: <0.001). CONCLUSIONS Cardiorespiratory dynamics from continuous ECG monitoring detect clinical deterioration in acute care patients and improve performance of conventional models that use only laboratory results and vital signs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

Detection of paroxysmal atrial fibrillation in acute stroke patients.

BACKGROUND Atrial fibrillation (AF) is a frequent cause of stroke, but detecting paroxysmal AF (pAF) poses a challenge. We investigated whether continuous bedside ECG monitoring in a stroke unit detects pAF more sensitively than 24-hour Holter ECG, and tested whether examining RR interval dynamics on short-term ECG recordings using an automated screening algorithm (ASA) for pAF detection is a u...

متن کامل

Insular cortex lesions, cardiac troponin, and detection of previously unknown atrial fibrillation in acute ischemic stroke: insights from the troponin elevation in acute ischemic stroke study.

BACKGROUND AND PURPOSE Detection rates of paroxysmal atrial fibrillation (AF) after acute ischemic stroke increase with duration of ECG monitoring. To date, it is unknown which patient group may benefit most from intensive monitoring strategies. Therefore, we aimed to identify predictors of previously unknown AF during in-hospital ECG monitoring. METHODS All consecutive patients with imaging-...

متن کامل

Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke.

BACKGROUND AND PURPOSE Cardioembolism in paroxysmal atrial fibrillation (pxAF) is a frequent cause of ischemic stroke. Sensitive detection of pxAF after stroke is crucial for adequate secondary stroke prevention; the optimal diagnostic modality to detect pxAF on stroke units is unknown. We compared 24-hour Holter electrocardiography (ECG) with continuous stroke unit ECG monitoring (CEM) for pxA...

متن کامل

Reliability and limitations of automated arrhythmia detection in telemetric monitoring after stroke.

BACKGROUND AND PURPOSE Guidelines recommend continuous ECG monitoring in patients with cerebrovascular events. Studies on intensive care units (ICU) demonstrated high sensitivity but high rates of false alarms of monitoring systems resulting in desensitization of medical personnel potentially endangering patient safety. Data on patients with acute stroke are lacking. METHODS One-hundred fifty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017