Bone grafting via reamer-irrigator-aspirator for nonunion of open Gustilo-Anderson type III tibial fractures treated with multiplanar external fixator

نویسندگان

  • Nicholas Kusnezov
  • Gautham Prabhakar
  • Matthew Dallo
  • Ahmed M. Thabet
  • Amr A. Abdelgawad
چکیده

INTRODUCTION The purpose of this investigation was to evaluate the outcomes following reamer-irrigator-aspirator (RIA) autogenous bone grafting (ABG) of high-grade open tibia fracture nonunions stabilized via multiplanar external fixation. METHODS We retrospectively reviewed all patients with Gustilo-Anderson type III open tibia fractures treated with multiplanar external fixation and who underwent RIA ABG for nonunion at our institutional Level 1 Trauma Center between 2008 and 2015. All patients between 15 and 65 years of age with a minimum of six-month follow-up were included. The primary outcomes of interest were achievement of union, time to union, and incidence of revision surgery. Complications and all-cause reoperation were recorded as secondary endpoints. RESULTS Fifteen patients met the inclusion criteria with a mean age of 41.1 ± 14.0 years. RIA ABG was harvested from the femur in all cases, with a mean volume of 34 ± 15 mL. At an average follow-up of 13.3 ± 6.8 months, all patients achieved union, including two who required repeat RIA ABG. One patient experienced a femoral shaft fracture four months following RIA that required intramedullary fixation. The average time to union was 6.0 ± 6.3 months. Twelve patients (80%) went on to union within six months and 13 (86.7%) within one year. Five patients experienced a total of six post-operative complications including three deep infections, one refracture through the nonunion site, and one gradual varus deformity. Two patients in this series required a subsequent RIA autografting procedure secondary to persistent nonunion despite initial RIA. CONCLUSION We found that RIA ABG offered a reliable solution to nonunion of Gustilo-Anderson type III open tibial fractures treated with multiplanar external fixation, circumventing the need to change the method of fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

Open Tibial Shaft Fractures; Treatment with External Fixator

.. Objective: The purpose of the study was to evaluate the clinical results after operative treatment of open tibia fractures (grade IIIA/B) with external fixator. Material and methods: 25 patients with open fractures of the tibial diaphysis, classified as type III A and B, according to the Gustilo classification, were operatively treated in Agency Headquarter Hospital Landikotal. All the patie...

متن کامل

Open tibial shaft fractures. Treatment with intramedullary nailing after provisional stabilization with non penetrating external fixator

Objective: To evaluate the incidence of union, nonunion, deep infection and factors influencing the time of bone healing in the treatment of open tibial shaft fractures Gustilo and Anderson types I and II initially treated with a non penetrating external fixator (Pinless®) followed by an unreamed intramedullary locked nail (UTN®). Methods: It is a prospective study of 39 open tibial shaft fract...

متن کامل

A New Technique for Obtaining Bone Graft in Cases of Distal Femur Nonunion: Passing a Reamer/Irrigator/Aspirator Retrograde Through the Nonunion Site.

Bone grafting is one of the most common orthopedic procedures. We conducted a study to assess the possibility of passing a Reamer/Irrigator/Aspirator (RIA; DePuy Synthes) retrograde through the nonunion site in distal femur cases. This technique would avoid the complications and discomfort associated with a separate entry site for RIA. All patients with a distal femur nonunion treated with RIA ...

متن کامل

External fixation for type III open tibial fractures.

An analysis of 51 type III open tibial fractures treated by external skeletal fixation is presented. The fractures are subdivided according to the classification of Gustilo, Mendoza and Williams (1984) into types IIIa, IIIb and IIIc. The different prognoses of these fracture subtypes is examined. The use of the Hoffmann and Hughes external fixators in the management of type III open tibial frac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017