Comparison of bispectral EEG analysis and auditory evoked potentials for monitoring depth of anaesthesia during propofol anaesthesia.

نویسندگان

  • R J Gajraj
  • M Doi
  • H Mantzaridis
  • G N Kenny
چکیده

We have compared the auditory evoked potential index (AEPIndex) and bispectral index (BIS) for monitoring depth of anaesthesia in spontaneously breathing surgical patients. Twenty patients (aged 17-49 yr) undergoing day surgery were anaesthetized with computer-controlled infusions of propofol. The mean (SD and range) of each measurement was determined during consciousness and unconsciousness and at specific times during the perioperative period. Mean values for AEPIndex during consciousness and unconsciousness were 74.5 (SD 14.7) 36.7 (7.1), respectively. BIS had mean values of 89.5 (SD 4.6) during consciousness and 48.8 (16.4) during unconsciousness. AEPIndex and BIS were greater during consciousness compared with during unconsciousness. The average awake values of AEPIndex were significantly higher than all average values during unconsciousness but this was not the case for BIS. BIS increased gradually during emergence from anaesthesia and may therefore be able to predict recovery of consciousness at the end of anaesthesia. AEPIndex was more able to detect the transition from unconsciousness to consciousness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index.

We studied four electrophysiological variables (bispectral index (BIS), 95% spectral edge frequency (SEF), median frequency (MF) and auditory evoked potential index (AEP index) in 10 patients during emergence from anaesthesia. We compared correlation of the signals with gradually decreasing calculated blood propofol concentrations, and evaluated the signal differences between preinduction and e...

متن کامل

Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness.

We have compared the auditory evoked potential (AEP) index (a numerical index derived from the AEP), 95% spectral edge frequency (SEF), median frequency (MF) and the bispectral index (BIS) during alternating periods of consciousness and unconsciousness produced by target-controlled infusions of propofol. We studied 12 patients undergoing hip or knee replacement under spinal anaesthesia. During ...

متن کامل

aepEX monitor for the measurement of hypnotic depth in patients undergoing balanced xenon anaesthesia.

BACKGROUND Previously, we showed a significant difference in the measurements of hypnotic depth by the bispectral index (BIS) and auditory-evoked potentials (AEPs) using the A-line autoregressive index during xenon anaesthesia. In the present study, we evaluate the alternative AEP-based auditory-evoked potential index (aepEX) for the measurement of hypnotic depth in patients undergoing general ...

متن کامل

Changes in the rapidly extracted auditory evoked potentials index and the bispectral index during sedation induced by propofol or midazolam under epidural block.

BACKGROUND The bispectral index (BIS) and the rapidly extracted auditory evoked potentials index (A-line ARX Index or AAI) have been proposed as methods to measure the depth of sedation. A prospective study was designed to assess the performance of both these methods for measuring the depth of sedation induced by propofol or midazolam under epidural block. METHODS Thirty-two ASA I and II adul...

متن کامل

EEG signal processing in anaesthesia. Use of a neural network technique for monitoring depth of anaesthesia.

BACKGROUND The Bispectral Index (BIS) is a proprietary index of anaesthesia depth, which is correlated with the level of consciousness and probability of intraoperative recall. The present study investigates the use of a neural network technique to obtain a non-proprietary index of the depth of anaesthesia from the processed EEG data. METHODS Two hundred patients, who underwent general abdomi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 1999