Cockcroft 07-33 ELECTROMAGNETIC BACKGROUND TESTS FOR THE ILC INTERACTION-POINT FEEDBACK SYSTEM
نویسندگان
چکیده
We present results obtained with the T-488 experiment at SLAC Endstation A (ESA). A material model of the ILC extraction-line design was assembled and installed in ESA. The module includes materials representing the mask, beamline calorimeter, and first extraction quadrupole, encompassing a stripline interaction-point feedback system beam position monitor (BPM). The SLAC high-energy electron beam was used to irradiate the module in order to mimic the electromagnetic (EM) backgrounds expected in the ILC interaction region. The impact upon the performance of the feedback BPM was measured, and compared with detailed simulations of its expected response.
منابع مشابه
The Electromagnetic Background Environment for the Interaction-point Beam Feedback System at the International Linear Collider
The Interaction Point (IP) feedback system is essential for maintaining the luminosity at the International Linear Collider (ILC). It is necessary to demonstrate the performance of the feedback beam position monitor (BPM) in an electron-positron pair background similar to that expected in the ILC interaction region (IR). We have simulated the ILC beam-beam interactions and used a GEANT model of...
متن کاملPhase Cross-correlation of the Wmap Ilc Map and Foregrounds
We present a circular cross-correlation tests for the phases of the Internal Linear Combination Map (ILC) and WMAP’s foregrounds for all K–W frequency bands at the range of multipoles l ≤ 50. We have found significant deviations from the expected Poissonian statistics for the ILC and the foregrounds phases. Our analysis shows that the low multipole range of the ILC power spectrum contains some ...
متن کاملDevelopment of a Positron Production Target for the Ilc Positron Source
The future International Linear Collider (ILC) will require of order 10 positrons per second to fulfil its luminosity requirements. The current baseline design produces this unprecedented flux of positrons using an undulatorbased source. In this concept, a collimated beam of photons produced from the action of an undulator on the main electron beam of the ILC is incident on a conversion target....
متن کاملInterstitial laser photocoagulation for treatment of benign prostatic hypertrophy: outcomes and cost effectiveness.
BACKGROUND We examined the efficiency and cost effectiveness of a temperature feedback diode-laser system in the treatment of benign prostatic hypertrophy (BPH). METHODS One hundred twenty patients with symptomatic BPH were included in this study between October 1997 and January 1998. Sixty of them were treated by transurethral resection of the prostate (TUR-P), and 60 patients were treated b...
متن کاملStability Conver Gence and Feedback Equiv Alence of Lti Iterative Learning Control
The goal of Iterative Learning Control ILC is to improve the accuracy of a system that repeatedly follows a reference trajectory This paper proves that for any causal ILC there is an equivalent feedback that achieves or approaches the ultimate ILC error with no iterations Remarkably this equivalent feedback depends only on the ILC operators and hence requires no plant knowledge This equivalence...