A Theoretically Based Pre-Reconstructing Filter for Spatio-Temporal Noise Reduction in Gated Cardiac SPECT

نویسندگان

  • Hongbing Lu
  • Guoping Han
  • Dongqing Chen
  • Lihong Li
  • Zhengrong Liang
چکیده

In dynamic SPECT studies, the acquired sinograms have both spatial and temporal correlations among the time sequence, in addition to the spatial correlation within each time frame (i.e., a three-dimensional (3D) sinogram). In this paper, we propose a theoretically based multi-frame filtering algorithm, which considers both the spatial and temporal correlations, for restoring the gated sinograms degraded by the Poisson noise. This spatio-temporal filtering task is greatly simplified by first applying the Anscombe transformation to all the sinogram data, which converts Poisson distributed noise into Gaussian distributed one with constant variance (i.e., the noise is signal independence). By performing temporal Karhune-Loève (K-L) transformation on the Anscombe transformed data sequence, the filtering task is further simplified from a 4D problem to a 3D spatial process. In the K-L domain, the noise property of constant variance remains for all components, while the signal-to-noise ratio decreases monotonically for lower eigenvalue components. An accurate Wiener filter is then constructed for each component of a 3D data set. By this approach, the spatiotemporal filtering can be achieved at a reasonable computational cost. The computer simulations are very encouraging, by visual judgement, as compared to frame -byframe 3D Wiener filtering along the time sequence.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Motion-compensated post-processing of gated cardiac SPECT images using a deformable mesh model

We present a post-reconstruction motion-compensated spatio-temporal filtering method for noise reduction in cardiac gated SPECT images. SPECT imaging suffers from low photon count due to radioactive dose limitations resulting in a high noise level in the reconstructed images. This is especially true in gated cardiac SPECT where the total number of counts is divided into a number of gates (time ...

متن کامل

Fast Analytical Reconstruction of Gated Cardiac SPECT with Non-Uniform Attenuation Compensation

Conventionally, the inverse problem of gated cardiac SPECT is solved by reconstructing the images frame-by-frame, ignoring the inter-frame correlation along the time dimension. To compensate for the non-uniform attenuation for quantitative cardiac imaging, iterative image reconstruction has been a choice which could utilize an a priori constraint on the inter-frame correlation for a penalized m...

متن کامل

Platelet-based MPLE algorithm for denoising of SPECT images: phantom and patient study

Introduction: In this study the evaluation of a Platelet-based Maximum Penalized Likelihood Estimation (MPLE) for denoising SPECT images was performed and compared with other denoising methods such as Wavelets or Butterworth filtration. Platelet-based MPLE factorization as a multiscale decomposition approach has been already proposed for better edges and surfaces representation due to Poi...

متن کامل

The prognostic value of stress/rest gated myocardial perfusion SPECT in patients with known or suspected coronary artery disease

Introduction:Gated myocardial perfusion SPECT has diagnostic and prognostic values in coronary artery disease (CAD). We tried to determine prognostic values of the left ventricular perfusion & functional indices as well as transient left ventricular dilation (TID) derived from gated myocardial perfusion SPECT. Methods: 1820patients who underwent gated myo...

متن کامل

Relationship between the optimum cut off frequency for Butterworth filter and lung-heart ratio in 99mTc myocardial SPECT

Background: We investigated whether the lungheart ratio parameter (LHR) can be used to identify the optimum cut off frequency for Butterworth filter in 99mTc myocardial SPECT imaging. Materials and Methods: This study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005