Hadamard transform ion mobility spectrometry.
نویسندگان
چکیده
Traditionally, the spectrum acquired using ion mobility spectrometry (IMS) is an average of multiple experimental cycles. Each cycle is initiated by passing a short burst of ions into a drift tube containing a homogeneous electric field. Prior to starting the subsequent cycle, all ions in the system must arrive at the detector or spectral overlap may occur. To maximize resolution, the ion pulse admitted to the drift tube is small in relation to the total scan time with the unfortunate consequence of an inherently low duty cycle (approximately 1%). Offering an improved SNR through a 50% duty cycle, the Hadamard transform (HT) applied to ion mobility spectrometry represents a fresh alternative to signal-averaged data acquisition. Initial results from measurements of amphetamine and cytochrome c samples indicate a 2-10-fold increase in SNR for the HT-IMS technique with no reduction in resolution.
منابع مشابه
Detecting and removing data artifacts in Hadamard transform ion mobility-mass spectrometry measurements.
Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and app...
متن کاملToward artifact-free data in Hadamard transform-based double multiplexing of ion mobility-Orbitrap mass spectrometry.
The integration of ion mobility spectrometry (IMS) with a trap-based mass spectrometer (MS) such as Orbitrap using the dual gate approach suffers from low duty cycle. Efforts to improve the duty cycle involve the utilization of Hadamard transform-based double multiplexing which significantly improves the signal-to-noise ratio and duty cycle of the ion mobility-Orbitrap mass spectrometry (IM-Orb...
متن کاملSelected ion flow-drift tube mass spectrometry, SIFDT-MS: quantification of volatile compounds in air and breath
A selected ion flow drift tube mass spectrometric analytical technique, SIFDT-MS, is described that extends the established selected ion flow tube mass spectrometry, SIFT-MS, by the inclusion of a static but variable E-field along the axis of the flow tube reactor in which the analytical ion-molecule chemistry occurs. The ion axial speed is increased in proportion to the reduced field strength ...
متن کاملA two-phase approach to Fourier transform ion mobility time-of-flight mass spectrometry.
It is well known that the duty cycle of common drift-tube ion mobility experiments is often below 1%. However, multiplexing approaches such as Fourier and Hadamard pulsing schemes have been shown to independently enhance the throughput of ion mobility spectrometry (IMS) experiments to levels that approach 50%. While challenges remain to their broad scale implementation we describe a new Fourier...
متن کاملHadamard Transform Time-of-Flight Mass Spectrometry
A new mode of operation of a time-of-flight mass spectrometer (TOFMS) is described and demonstrated. A continuous ion beam emerging from the ion source is accelerated and then modulated by a pseudorandom sequence of “on” and “off” pulses. The data acquisition period is set to match the period of the modulation sequence, and data are acquired synchronously with the modulation of the ion beam. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 78 13 شماره
صفحات -
تاریخ انتشار 2006