The fundus slit lamp

نویسنده

  • Marcus-Matthias Gellrich
چکیده

Fundus biomicroscopy with the slit lamp as it is practiced widely nowadays was not established until the 1980-es with the introduction of the Volk lenses +90 and +60D. Thereafter little progress has been made in retinal imaging with the slit lamp. It is the aim of this paper to fully exploit the potential of a video slit lamp for fundus documentation by using easily accessible additions. Suitable still images are easily retrieved from videorecordings of slit lamp examinations. The effects of changements in the slit lamp itself (slit beam and apertures) and its examination equipment (converging lenses from +40 to +90D) on quality and spectrum of fundus images are demonstrated. Imaging software is applied for reconstruction of larger fundus areas in a mosaic pattern (Hugin®) and to perform the flicker test in order to visualize changes in the same fundus area at different points of time (Power Point®). The three lenses +90/+60/+40D are a good choice for imaging the whole spectrum of retinal diseases. Displacement of the oblique slit light can be used to assess changes in the surface profile of the inner retina which occurs e.g. in macular holes or pigment epithelial detachment. The mosaic function in its easiest form (one strip macula adapted to one strip with the optic disc) provides an overview of the posterior pole comparable to a fundus camera's image. A reconstruction of larger fundus areas is feasible for imaging in vitreoretinal surgery or occlusive vessel disease. The flicker test is a fine tool for monitoring progressive glaucoma by changes in the optic disc, and it is also a valuable diagnostic tool in macular disease. Nearly all retinal diseases can be imaged with the slit lamp - irrespective whether they affect the posterior pole, mainly the optic nerve or the macula, the whole retina or only its periphery. Even a basic fundus controlled perimetry is possible. Therefore fundus videography with the slit lamp is a worthwhile approach especially for the many ophthalmologists without access to the most recent diagnostic equipment or a professional photographer at hand.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mosaicking and enhancement of slit lamp biomicroscopic fundus images.

AIMS To process video slit lamp biomicroscopic fundus image sequences in order to generate wide field, high quality fundus image montages which might be suitable for photodocumentation. METHODS Slit lamp biomicroscopic fundus examination was performed on human volunteers with a contact or non-contact lens. A stock, charge coupled device camera permitted image capture and storage of the image ...

متن کامل

Photographic recording of slit-lamp appearances of the ocular fundus.

The four methods of illumination in the use of slit-lamp biomicroscopy of the anterior segment, described first by Vogt, are equally useful in the posterior part of the eye. Examination of the ocular fundus is more difficult. In particular, photography of the central and peripheral parts of the fundus demands additional technical arrangements if all the appearances of biomicroscopy are to be re...

متن کامل

Automated, real time extraction of fundus images from slit lamp fundus biomicroscope video image sequences.

AIMS Slit lamp fundus biomicroscopy allows for high magnification, stereoscopic diagnosis, and treatment of macular diseases. Variable contrast, narrow field of view, and specular reflections arising from the cornea, sclera, and examining lens reduce image quality; these images are of limited clinical utility for diagnosis, treatment planning, and photodocumentation when compared with fundus ca...

متن کامل

Bracket for attaching the Kowa fundus camera to the Haag-Streit 900 slit lamp.

A bracket has been designed to allow a Kowa RC II fundus camera to be mounted firmly on a Haag-Streit goo slit lamp. The bracket provides a steady support which is of particular importance in fluorescein fundus angiography. The bracket consists oftwo parts. The upper part of mild steel and finished in satin chrome fits into the camera shoe and can be locked into place. The lower part is black a...

متن کامل

Video indirect ophthalmoscopy using a hand-held video camera

Fundus photography in adults and cooperative children is possible with a fundus camera or by using a slit lamp-mounted digital camera. Retcam TM or a video indirect ophthalmoscope is necessary for fundus imaging in infants and young children under anesthesia. Herein, a technique of converting and using a digital video camera into a video indirect ophthalmoscope for fundus imaging is described. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2015