Changes in pulse pressure variability during cardiac resynchronization therapy in mechanically ventilated patients

نویسندگان

  • Cornelius Keyl
  • Jochem Stockinger
  • Sven Laule
  • Klaus Staier
  • Jochen Schiebeling-Römer
  • Christoph Wiesenack
چکیده

INTRODUCTION The respiratory variation in pulse pressure (PP) has been established as a dynamic variable of cardiac preload which indicates fluid responsiveness in mechanically ventilated patients. The impact of acute changes in cardiac performance on respiratory fluctuations in PP has not been evaluated until now. We used cardiac resynchronization therapy as a model to assess the acute effects of changes in left ventricular performance on respiratory PP variability without the need of pharmacological intervention. METHODS In 19 patients undergoing the implantation of a biventricular pacing/defibrillator device under general anesthesia, dynamic blood pressure regulation was assessed during right ventricular and biventricular pacing in the frequency domain (power spectral analysis) and in the time domain (PP variation: difference between the maximal and minimal PP values, normalized by the mean value). RESULTS PP increased slightly during biventricular pacing but without statistical significance (right ventricular pacing, 33 +/- 10 mm Hg; biventricular pacing, 35 +/- 11 mm Hg). Respiratory PP fluctuations increased significantly (logarithmically transformed PP variability -1.27 +/- 1.74 ln mm Hg2 versus -0.66 +/- 1.48 ln mm Hg2; p < 0.01); the geometric mean of respiratory PP variability increased 1.8-fold during cardiac resynchronization. PP variation, assessed in the time domain and expressed as a percentage, showed comparable changes, increasing from 5.3% (3.1%; 12.3%) during right ventricular pacing to 6.9% (4.7%; 16.4%) during biventricular pacing (median [25th percentile; 75th percentile]; p < 0.01). CONCLUSION Changes in cardiac performance have a significant impact on respiratory hemodynamic fluctuations in ventilated patients. This influence should be taken into consideration when interpreting PP variation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese.

Respiration variation in arterial pulse pressure (ΔPP) and pulse oximetry plethysmographic waveform amplitude (ΔPOP) are accurate predictors of fluid responsiveness in mechanically ventilated patients. We hypothesized that stroke volume variation (SVV) and pleth variability index (PVI) can predict fluid responsiveness in mechanically ventilated patients during major surgical procedures in H...

متن کامل

Relationship Between Changes in Pulse Pressure and Frequency Domain Components of Heart Rate Variability During Short-Term Left Ventricular Pacing in Patients with Cardiac Resynchronization Therapy

BACKGROUND The aim of the study was to explore the relationship between changes in pulse pressure (PP) and frequency domain heart rate variability (HRV) components caused by left ventricular pacing in patients with implanted cardiac resynchronization therapy (CRT). MATERIAL AND METHODS Forty patients (mean age 63±8.5 years) with chronic heart failure (CHF) and implanted CRT were enrolled in the...

متن کامل

Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.

BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...

متن کامل

The ability of pleth variability index to predict the hemodynamic effects of positive end-expiratory pressure in mechanically ventilated patients under general anesthesia.

BACKGROUND Pleth variability index (PVI) is a new algorithm allowing automated and continuous monitoring of respiratory variations in the pulse oximetry plethysmographic waveform amplitude. PVI can predict fluid responsiveness noninvasively in mechanically ventilated patients during general anesthesia. We hypothesized that PVI could predict the hemodynamic effects of 10 cm H2O positive end-expi...

متن کامل

Pleth Variability Index predicts fluid responsiveness in critically ill patients

OBJECTIVE To investigate whether the pleth variability index, a noninvasive and continuous tool, can predict fluid responsiveness in mechanically ventilated patients with circulatory insufficiency. DESIGN Prospective study. SETTING Surgical intensive care unit of a university hospital. PATIENTS Forty mechanically ventilated patients with circulatory insufficiency in whom volume expansion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2007