چکیده

PURPOSE To investigate the integration of subretinal implants containing full-depth perforations of various widths with rat and pig retina across weeks of implantation. METHODS In transgenic P23H rhodopsin line 1 (TgP23H-1) rats and wild-type (WT) pigs, we examined four subretinal implant designs: solid inactive polymer arrays (IPA), IPAs with 5- or 10-μm wide perforations, and active bipolar photovoltaic arrays (bPVA) with 5-μm perforations. We surgically placed the implants into the subretinal space using an external approach in rats or a vitreoretinal approach in pigs. Implant placement in the subretinal space was verified with optical coherence tomography and retinal perfusion was characterized with fluorescein angiography. Rats were sacrificed 8 or 16 weeks post-implantation (wpi) and pigs 2, 4, or 8 wpi, and retinas evaluated at the light microscopic level. RESULTS Regardless of implant design, retinas of both species showed normal vasculature. In TgP23H-1 retinas implanted with 10-μm perforated IPAs, inner nuclear layer (INL) cells migrated through the perforations by 8 wpi, resulting in significant INL thinning by 16 wpi. Additionally, these retinas showed greater pseudo-rosette formation and fibrosis compared with retinas with solid or 5-μm perforated IPAs. TgP23H-1 retinas with bPVAs showed similar INL migration to retinas with 5-μm perforated IPAs, with less fibrosis and rosette formation. WT pig retina with perforated IPAs maintained photoreceptors, showed no migration, and less pseudo-rosette formation, but more fibrosis compared with implanted TgP23H-1 rat retinas. CONCLUSIONS In retinas with photoreceptor degeneration, solid implants, or those with 5-μm perforations lead to the best biocompatibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Morphological changes in injured retinal pigment epithelium and photoreceptor cells after transplantation of stem cells into subretinal space

Introduction: Degenerative retinal diseases are main cause of irreversible blindness. Stem cells therapy is a promising way in these diseases. Therefore, mesenchymal stem cells because of its safety can produce degenerated cells and can play important role in treatment. The aim of this study was to examine morphological changes in injured retinal pigment epithelium (RPE) and photoreceptor cells...

متن کامل

Effect of shape and coating of a subretinal prosthesis on its integration with the retina.

Retinal stimulation with high spatial resolution requires close proximity of electrodes to target cells. This study examines the effects of material coatings and 3-dimensional geometries of subretinal prostheses on their integration with the retina. A trans-scleral implantation technique was developed to place microfabricated structures in the subretinal space of RCS rats. The effect of three c...

متن کامل

Subretinal Perfluorocarbon Liquid (PFCL) after Vitrectomy; A Case Report And Review of Literature

Purpose: To report a case of retained subretinal perfluorocarbon liquid (PFCL) after vitrectomy and to discuss the diagnosis and management of subretinal PFCL based on literature review. Case Report: A 57-year-old female patient underwent 3-port 23-gauge vitrectomy for advanced proliferative diabetic retinopathy and combined tractional and rhegmatogenous retinal detachment. During the surgery, ...

متن کامل

Migration of retinal cells through a perforated membrane: implications for a high-resolution prosthesis.

PURPOSE One of the critical difficulties in design of a high-resolution retinal implant is the proximity of stimulating electrodes to the target cells. This is a report of a phenomenon of retinal cellular migration into a perforated membrane that may help to address this problem. METHODS Mylar membranes with an array of perforations (3-40 microm in diameter) were used as a substrate for in vi...

متن کامل

The Use of an Axisymmetric Formulation of the Finite Volume Method for the Thermal Analysis of the Retina and Ocular Tissues Following Implantation of Retinal Prosthesis

This study analyzes the heat transfer in human eyes following implantation of retinal prostheses using an axisymmetric formulation of the Finite Volume Method. The model used consisted of a vertex centered unstructured grid finite volume method in an edgebased data structure and an explicit time integration. The results of the finite volume thermal analysis in ocular tissues were determined in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Translational vision science & technology

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2015