Half time of the diastolic aortoventricular pressure difference by continuous wave Doppler ultrasound: a measure of the severity of aortic regurgitation?

نویسندگان

  • S O Samstad
  • L Hegrenaes
  • T Skjaerpe
  • L Hatle
چکیده

Thirty four patients with aortic regurgitation were studied by continuous wave Doppler ultrasound. In 30 of these the regurgitation was graded by cineangiography as mild, moderate, or severe and in four severe regurgitation was confirmed at operation. The half times of the aortoventricular pressure differences obtained with Doppler compared well with those obtained from pressure recordings at catheterisation. The relation between pressure half times and cineangiographic gradings of severity was not consistent. Similarly, a control group of patients without aortic regurgitation showed a wide range of the invasively recorded pressure half times which overlapped with those in patients with aortic regurgitation. This suggests that factors such as systemic vascular resistance, and aortic and left ventricular compliance can have an appreciable effect on the pressure half time. If these factors are not included the method will be of limited value, except in patients with pressure half times of less than 300 ms, when regurgitation invariably is severe. These results suggest that at present the method is of value only in recognising the patients with the most severe aortic regurgitation who need early operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative assessment of the hemodynamic consequences of aortic regurgitation by means of continuous wave Doppler recordings.

The purpose of this study was to evaluate the ability of continuous wave Doppler ultrasound recordings to reflect the magnitude and hemodynamic effects of aortic regurgitation. Forty-five patients with angiographically proved aortic regurgitation had Doppler studies performed within 24 hours of cardiac catheterization. High quality spectral recordings of the regurgitant jet were obtained in 31 ...

متن کامل

Effect of load alterations on the effective regurgitant orifice area in chronic aortic regurgitation.

OBJECTIVE To evaluate the load dependence of effective regurgitant orifice area (ROA) in an animal model of chronic aortic regurgitation. METHODS Eight sheep were studied 10-20 weeks after the surgical creation of aortic regurgitation. After baseline studies, 500 ml of blood, angiotensin II, and nitroprusside were infused sequentially. Electromagnetic flow meters were used as reference standa...

متن کامل

Characteristic Doppler echocardiographic pattern of mitral inflow velocity in severe aortic regurgitation.

In symptomatic severe aortic regurgitation, left ventricular diastolic pressure increases rapidly, often exceeding left atrial pressure in late diastole. This characteristic hemodynamic change should be reflected in the Doppler mitral inflow velocity, which is the direct result of the diastolic pressure difference between the left ventricle and left atrium. Mitral inflow velocity was obtained b...

متن کامل

Quantitative evaluation of aortic insufficiency by continuous wave Doppler echocardiography.

To assess the usefulness of continuous wave Doppler echocardiography in the evaluation of aortic insufficiency, the aortic regurgitant flow velocity pattern obtained with continuous wave Doppler examination was compared with the results of aortography and conventional pulsed Doppler techniques in 25 individuals with aortic insufficiency. The diastolic deceleration slope as measured from the con...

متن کامل

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 1989