Sequence-based typing of Legionella pneumophila strains isolated from hospital water distribution systems as a complementary element of risk assessment of legionellosis in Poland.

نویسنده

  • Katarzyna Pancer
چکیده

Many factors affect the risk of Legionella infection, such as the design, construction and maintenance of water distribution systems, the presence of individuals who may be exposed and their vulnerability to infection, and the degree of water system colonization and properties of Legionella strains. For epidemiological investigations, two properties of the Legionella strains are usually determined: serotyping and genotyping (sequence-based typing, SBT). In Poland, data regarding legionellosis are fragmentary, despite the fact that this has been a notifiable disease since 2002. The number of reported cases is very low; moreover, the main method of diagnosis is serological examination (delayed diagnosis and cheaper methods), and only single cases of LD were confirmed by culture of bacteria. Therefore, after 10 years of mandatory reporting of the Legionella spp. infection in Poland, the real epidemiological situation is still unknown; however, risk assessment should be carried out, especially in hospitals. In the presented study, comparison of the sequence types of 111 isolated L. pneumophila strains (from hospital water systems) with those present in the EWGLI SBT data was undertaken for complex risk analysis as a complementary element. In total, strains of L. pneumophila belonging to 12 out of 19 STs determined in the presented study were previously reported to the EWGLI SBT database (ST1, ST42, ST59, ST81, ST87, ST114, ST152, ST191, ST371, ST421, ST461, ST520). Among these strains, only 7 STs were previously reported in the amount of ≥10 (mainly ST1, ST42, ST81). Analysis of EWGLI data were carried out and, proportionally, the highest percentage of hospital-acquired strains (clinical and environmental) was found for ST 81, ST421 and ST152, but the largest number was for ST1. Based on the EWGLI data and the presented results, it was found that persistent colonization of HWS of 3 hospitals by strains belonging to ST42, ST1, ST87 indicated an increased risk of legionellosis, especially ST42.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Insertion sequences as highly resolutive genomic markers for sequence type 1 Legionella pneumophila Paris.

The causative agent of legionellosis, Legionella pneumophila, colonizes all natural and human-made water networks, thus constituting the source of contaminated aerosols responsible for airborne human infections. Efficient control of infections, especially during epidemics, necessitates the fastest and most resolutive identification possible of the bacterial source for subsequent disinfection of...

متن کامل

Isolation of Legionella Pneumophila Serogroups 1, 8 & 10 (Causative Agents of Legionnaires\' Disease) from Water Sources in Tehran, Iran

In this survey, 187 samples collected from 9 different sources of water in Tehran such as: water cool‌ers, neonates incubators, water bathes (37° C), little pools in parks or squares, cooling towers, hot or cold water taps, were examined for Legionnaires' disease agents. Inoculating water samples on selec‌tive and nonselective media resulted in isolation of several strains of gram negative bact...

متن کامل

Energy Conservation and the Promotion of Legionella pneumophila Growth: The Probable Role of Heat Exchangers in a Nosocomial Outbreak

OBJECTIVE To determine the source of a Legionella pneumophila serogroup 5 nosocomial outbreak and the role of the heat exchanger installed on the hot water system within the previous year. SETTING A 400-bed tertiary care university hospital in Sherbrooke, Canada. METHODS Hot water samples were collected and cultured for L. pneumophila from 25 taps (baths and sinks) within wing A and 9 taps in w...

متن کامل

Molecular typing of nosocomial isolates of Legionella pneumophila serogroup 3.

In Paris, France, an outbreak of pneumonia due to Legionella pneumophila serogroup 3 was observed in Necker (four cases) and Pitié (six cases) hospitals. Neither the 10 clinical isolates nor 5 tap water isolates from Necker Hospital harbored plasmids. Clinical and environmental serogroup 3 isolates and serogroup 3 reference strain Bloomington 2 were analyzed by chromosomal probe fingerprinting....

متن کامل

Virulence of Legionella pneumophila strains isolated from hospital water system and healthcare-associated Legionnaires’ disease in Northern Italy between 2004 and 2009

BACKGROUND Worldwide, L. pneumophila sg 1 is the most common agent of Legionnaires' disease ( 80 to 90% of the reported cases). In contrast, L. pneumophila sg 2-14 account for only 15 to 20% of community-acquired cases, although they account for over 50% of the environmental isolates. The discrepancy between environmental isolates and clinical cases of disease suggested that there are differenc...