Bioelectrical Impedance and Dual-Energy X-Ray Absorptiometry Assessments of Changes in Body Composition Following Exercise in Patients with Type 2 Diabetes Mellitus

نویسندگان

  • Masae Miyatani
  • Pearl Yang
  • Scott Thomas
  • B. Catharine Craven
  • Paul Oh
چکیده

We aimed to compare the level of agreement between leg-to-leg bioelectrical impedance analysis (LBIA) and dual-energy X-ray absorptiometry (DXA) for assessing changes in body composition following exercise intervention among individuals with Type 2 diabetes mellitus (T2DM). Forty-four adults with T2DM, age 53.2 ± 9.1 years; BMI 30.8 ± 5.9 kg/m(2) participated in a 6-month exercise program with pre and post intervention assessments of body composition. Fat free mass (FFM), % body fat (%FM) and fat mass (FM) were measured by LBIA (TBF-300A) and DXA. LBIA assessments of changes in %FM and FM post intervention showed good relative agreements with DXA variables (P < 0.001). However, Bland-Altman plot(s) indicated that there were systematic errors in the assessment of the changes in body composition using LBIA compared to DXA such that, the greater the changes in participant body composition, the greater the disparity in body composition data obtained via LBIA versus DXA data (FFM, P = 0.013; %FM, P < 0.001; FM, P < 0.001). In conclusion, assessment of pre and post intervention body composition implies that LBIA is a good tool for assessment qualitative change in body composition (gain or loss) among people with T2DM but is not sufficiently sensitive to track quantitative changes in an individual's body composition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioelectrical impedance analysis (BIA) using bipolar foot electrodes in the assessment of body composition in Type 2 diabetes mellitus.

The use of bioelectrical impedance analysis (BIA) for determining human body composition is widely accepted as a safe, rapid, and reliable technique. Although this technique has been validated in normal and obese individuals, only limited studies have been done in special populations. The use of BIA for the measurement of body composition in Type 2 (non-insulin dependent) diabetic patients woul...

متن کامل

Body composition methods: comparisons and interpretation.

The incidence of obesity in the United States and other developed countries is epidemic. Because the prevalence of comorbidities to obesity, such as type 2 diabetes, has also increased, it is clear there is a great need to monitor and treat obesity and its comorbidities. Body composition assessments vary in precision and in the target tissue of interest. The most common assessments are anthropo...

متن کامل

Comparisons of a Multi-Frequency Bioelectrical Impedance Analysis to the Dual-Energy X-Ray Absorptiometry Scan in Healthy Young Adults Depending on their Physical Activity Level

This study aimed at comparing BIA and DXA results in assessing body composition in young adults depending on their physical activity level. Eighty healthy 19-30 years old subjects were enrolled and their body composition (Fat Mass and Fat-Free Mass) was assessed by dual-energy X-ray absorptiometry (DXA) and by a newly developed Bioelectrical Impedance Analyzer (BIA - Tanita MC780). A seven-day ...

متن کامل

Relationships among dual-energy X-ray absorptiometry, bioelectrical impedance and ultrasound measurements of body composition of swine

In three separate studies (156 pigs total), dual-energy X-ray absorptiometry (DXA), bioelectrical impedance (BIA) and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body lean mass and ultrasound measurements ...

متن کامل

New bioelectrical impedance formula for patients with respiratory insufficiency: comparison to dual-energy X-ray absorptiometry.

Malnutrition in patients with severe respiratory insufficiency can lead to severe complications, justifying the use of objective nutritional assessment techniques, such as bioelectrical impedance analysis (BIA), which is an easy, noninvasive method of measuring body composition. The purpose of this study was to develop, and validate against dual-energy X-ray absorptiometry (DXA), a BIA formula ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012