Effect of Saliva Contamination on Microleakage Beneath Bonded Brackets: A Comparison Between Two Moisture-Tolerant Bonding Systems

نویسندگان

  • Mohammad Hossein Toodehzaeim
  • Navid Rezaie
چکیده

OBJECTIVES This study aimed to evaluate the effects of saliva contamination on the metallic bracket microleakage bonded with two moisture-tolerant bonding systems. MATERIALS AND METHODS Ninety freshly extracted premolar teeth were randomly divided into six groups of 15 with the following treatments: G1 (control): After acid etching, Assure primer and Assure adhesive were applied to non-contaminated enamel surfaces. G2 (contaminated after etching): The etched enamel surface was exposed to saliva, then Assure primer and Assure adhesive were applied. G3 (contaminated after priming): Saliva contamination was done after application of Assure primer. The exact same procedures were applied to groups G4 to G6 except that TIMP primer and Transbond Plus adhesive system were used. To measure the microleakage score, the teeth were stained with 2% methylene blue for 24 hours, sectioned and examined under a stereomicroscope at ×16 magnification. Data analysis was performed using Fisher's exact test. RESULTS In dry conditions, Assure and TMIP were not significantly different in terms of microleakage scores. All contaminated groups exhibited higher microleakage score at the enamel/adhesive interface compared to the bracket/adhesive interface (P< 0.01). In wet conditions, Assure groups showed higher microleakage at the enamel-adhesive interface compared to the TMIP groups (P<0.05). At the bracket-adhesive interface, the microleakage scores were not significantly different in saliva contaminated groups compared to the controls. CONCLUSION Saliva contamination caused greater microleakage at the enamel-adhesive interface compared to the adhesive-bracket interface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage under Orthodontic Metal Brackets Bonded with Three Different Bonding Techniques with/without Thermocycling

Introduction: The aim of this study was to compare the microleakage of beneath the orthodontic brackets bonded with 3 different bonding techniques and evaluate the effect of thermocycling. Methods: One hundred and twenty premolars were randomly divided into 6 groups, received the following treatment: group 1: 37% phosphoric acid gel+Unite primer+Unite adhesive, group 2: 37% phosphoric acid gel+...

متن کامل

Effect of Saliva Contamination and sequencing time of curing the Transbond™ Plus Self Etching Primer on the Shear Bond Strength of Orthodontic Brackets

Abstract Background and aim: Over the years, improvments have been done to simplify clinical bonding procedure. One of these material is Transbond™ Plus Self Etching. The aim of this study was to evaluate the effect of saliva contamination and reusing Transbond™ Plus Self Etching Primer (SEP) on shear bond strength of orthodontic brackets. Materials and Methods: Fifty premolars divided into fiv...

متن کامل

Comparative evaluation of shear bond strength of metallic brackets bonded with two different bonding agents under dry conditions and with saliva contamination.

BACKGROUND This study compared the shear bond strength of metallic brackets bonded with Single Bond and Assure bonding agents under dry and saliva-contamination conditions. METHODS Sixty sound premolar teeth were selected, and stainless-steel brackets were bonded on enamel surfaces with Single Bond and Assure bonding agents under dry condition or with saliva contamination. Shear bond strength...

متن کامل

In vitro Effects of a Neutral Fluoride Agent on Shear Bond Strength and Microleakage of Orthodontic Brackets

Introduction: This study aimed to evaluate the effect of pretreatment with a neutral fluoride agent on shear bond strength (SBS) and microleakage of orthodontic brackets, and to investigate any significant relationship between SBS and microleakage. Methods: Forty intact premolars were selected and randomly divided into 2 groups. Group 1 served as the control, while group 2 underwent treatment w...

متن کامل

Microleakage under orthodontic brackets bonded with different adhesive systems

OBJECTIVE This in vitro study aimed to compare the microleakage of orthodontic brackets between enamel-adhesive and adhesive-bracket interfaces at the occlusal and gingival margins bonded with different adhesive systems. MATERIALS AND METHODS A total of 144 human maxillary premolar teeth extracted for orthodontic reasons was randomly divided into four groups. Each group was then further divid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015