Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques

نویسندگان

  • Ying Zhou
  • Yong Li
  • Xiao Ma
  • Yiqing Huang
  • Jiawei Wang
چکیده

PURPOSE This study evaluated the effect of span length on the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques. MATERIALS AND METHODS Models with two solid abutment analogs at different inter-abutment distances were digitized using a laboratory scanner. Frameworks of two-, three-, and four-unit fixed prostheses were designed by a computer. Six dots with a diameter of 0.2 mm were preset on the surface of each framework. A total of 54 implant-supported cobalt chromium frameworks were fabricated by milling, selective laser melting (SLM), and cast techniques. The frameworks were scanned and exported as Stereolithography files. Distances between two dots in X, Y, and Z coordinates were measured in both the designed and fabricated frameworks. Marginal gaps between the framework and the abutments were also evaluated by impression replica method. RESULTS In terms of distance measurement, significant differences were found between three- and four-unit frameworks, as well as between two- and four-unit frameworks prepared by milling technique (P<.05). Significant differences were also noted between two- and three-unit frameworks, as well as between two- and four-unit frameworks prepared by cast technique (P<.05). The milling technique presented smaller differences than the SLM technique, and the SLM technique showed smaller differences than the cast technique at any unit prostheses (P<.05). Evaluation with the impression replica method indicated significant differences among the span lengths for any fabrication method (P<.05), as well as among the fabrication methods at any unit prostheses (P<.05). CONCLUSION The adaptation of implant-supported cobalt chromium frameworks was affected by the span length and fabrication method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fit Analysis of Different Framework Fabrication Techniques for Implant-Supported Partial Prostheses.

PURPOSE This study evaluated the vertical misfit of implant-supported frameworks made using different techniques to obtain passive fit. MATERIALS AND METHODS Thirty three-unit fixed partial dentures were fabricated in cobalt-chromium alloy (n = 10) using three fabrication methods: one-piece casting, framework cemented on prepared abutments, and laser welding. The vertical misfit between the f...

متن کامل

Dimensional changes of three-unit implant-supported zirconia frameworks from scanning to sintering

Background and Aims: Passive fitness of implant frameworks are important factors for long-term success of dental implant restorations. The aim of this in vitro study was to evaluate the dimensional changes of implant supported zirconia frameworks fabricated by Zirkonzahn CAD/CAM system during fabrication stages. Materials and Methods: The master model of 3-unit FDP was made of two implant abut...

متن کامل

Shear Bond Strength of Porcelain Veneering to Nickel-Chromium, Chromium-Cobalt, Zirconia and Lithium Disilicate

Background and Aim: High chipping rates of the veneering porcelain in zirconia ce-ramic restorations have been reported in many clinical studies. However, information on the bonding behavior of veneering porcelain to zirconia and lithium disilicate frameworks is limited. The purpose of this study was to evaluate the bond-ing strength of porcelain veneering to zirconia, lithium disilicate, nicke...

متن کامل

Stress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis

Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...

متن کامل

The precision of fit of cast and milled full-arch implant-supported restorations.

PURPOSE The purpose of this study was to investigate the marginal precision of computer numeric control-milled frameworks fabricated of grade 4 commercially pure titanium or cobalt-chrome alloy through digital technology and to compare them with conventional cast frameworks. MATERIAL AND METHODS A titanium cast of a mandibular arch with six implant analogs was used as a master. The master cas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017