Point-of-care focused cardiac ultrasound for the assessment of thoracic aortic dimensions, dilation, and aneurysmal disease.
نویسندگان
چکیده
OBJECTIVES Thoracic aortic aneurysm and thoracic aortic dissection are related and potentially deadly diseases that present with nonspecific symptoms. Transthoracic echocardiography (TTE) may detect thoracic aortic pathology and is being increasingly performed by the emergency physician at the bedside; however, the accuracy of point-of-care (POC) focused cardiac ultrasound (FOCUS) for thoracic aortic aneurysm and thoracic aortic dissection has not been studied. The objective of this pilot study was to explore the agreement, sensitivity, and specificity of FOCUS for thoracic aortic dimensions, dilation, and aneurysm compared with CT angiography (CTA) as the reference standard. METHODS This study was a retrospective pilot analysis of image and chart data on consecutive patients presenting to an urban, academic emergency department (ED) between January 2008 and June 2010, who had both a FOCUS and a CTA for suspicion of thoracic aorta pathology. Thoracic aorta dimensions were measured from recordings by three ultrasound-trained emergency physicians blinded to any initial FOCUS and CTA results. CTA measurements were obtained by a radiologist blinded to the FOCUS results. Using cutoffs of 40 and 45 mm, we calculated the sensitivity and specificity of FOCUS for aortic dilation and aneurysm with the largest measurement on CT as the reference standard. Bland-Altman plots with 95% limits of agreement were used to demonstrate agreement for aortic measurements, kappa statistics to assess the degree of agreement between tests for aortic dilation, and intraclass correlation for interobserver and intraobserver variability. RESULTS Ninety-two patients underwent both FOCUS and CTA during the study period. Ten FOCUS studies had inadequate visualization for all measurements areas. Eighty-two patients were included in the final analysis. Mean (±SD) age was 58.1 (±16.6) years and 58.5% were male. Sensitivity, specificity, and the observed kappa value (95% confidence interval [CI]) between FOCUS and CTA for the presence of aortic dilation at the 40-mm cutoff were 0.77 (95% CI = 0.58 to 0.98), 0.95 (95% CI = 0.84 to 0.99), and 0.74 (95% CI = 0.58 to 0.90), respectively. The mean difference (95% limits of agreement) for the Bland-Altman plots was 0.6 mm (-5.3 to 6.5) for the sinuses of Valsalva, 4 mm (-2.7 to 10.7) for the sinotubular junction, 1.5 mm (-5.8 to 8.8) for the ascending aorta, and 2.2 mm (-5.9 to 10.3) for the descending aorta. CONCLUSIONS In this retrospective pilot study, FOCUS demonstrated good agreement with CTA measurements of maximal thoracic aortic diameter. FOCUS appears to be specific for aortic dilation and aneurysm when compared to CTA, but requires further prospective study.
منابع مشابه
Focused cardiac ultrasound diagnosis of thoracic aortic aneurysm: two cases.
BACKGROUND Thoracic aortic aneurysms (TAAs) are less prevalent than abdominal aortic aneurysms. Symptomatic TAAs need to be identified quickly by the emergency physician (EP) since mortality rates increase dramatically once complications such as rupture or dissection occur. Compared with validated EP-performed ultrasound of the abdominal aorta, EP-performed focused cardiac ultrasound that inclu...
متن کاملDiagnosis of a pericardial effusion with a thoracic aortic aneurysm by point-of-care ultrasound.
We present a rare case of a young patient with chest pain whose ascending thoracic aortic aneurysm (TAA) was detected by point-of-care ultrasound (POCUS) leading to a successful surgical repair. POCUS identified a moderate pericardial effusion and an associated severely dilated ascending aorta. In this context, it is important to rule out aortic rupture and aortic dissection. We also discuss th...
متن کاملDiagnostic performance of focused cardiac ultrasound performed by emergency physicians for the assessment of ascending aorta dilation and aneurysm.
OBJECTIVES The diagnostic performance of transthoracic focused cardiac ultrasound (FoCUS) performed by emergency physicians (EP) to estimate ascending aorta dimensions in the acute setting has not been prospectively studied. The diagnostic accuracy and the interobserver variability of EP-performed FoCUS were investigated to estimate thoracic aortic dilation and aneurysm compared with the result...
متن کاملLate lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm
We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.
متن کاملThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Academic emergency medicine : official journal of the Society for Academic Emergency Medicine
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2012