Quality of vision in patients implanted with aspherical and spherical intraocular lens: Intraindividual comparison
نویسندگان
چکیده
AIMS To compare the quality of vision in pseudophakic patients implanted with aspherical and spherical intraocular lenses (IOLs). MATERIALS AND METHODS Randomized prospective longitudinal intrapatient comparison between aspherical and spherical IOLs performed on 22 patients who underwent bilateral cataract surgery. Best corrected visual acuity, subjective contrast sensitivity, Strehl ratio and spherical aberrations (SA), and higher order wavefront aberrations for a 3.5 mm and a 6.0 mm pupil were measured after 3 months of cataract surgery. RESULTS SA (Z4,0) decreased significantly in eyes with aspherical IOL implant (P = 0.004). Modulation transfer function (MTF) and point spread function (PSF) resulted no significant difference between the two groups (P = 0.87; P = 0.32). CONCLUSION Although the SA is significantly lower in eyes implanted with aspherical IOL, the quality of vision determined with MTF and PSF does not significantly differ for subjective and objective parameters that were analyzed.
منابع مشابه
Quels bénéfices visuels peut-on attendre d’un implant sans aberration sphérique dans la chirurgie de la cataracte ?
Purpose: To assess the quality of vision in pseudophakic patients with aspheric intraocular lens (IOL) without spherical aberration compared to patients with spherical IOL. Methods: Twenty-four patients (48 eyes) undergoing cataract surgery were randomly divided into two groups: 12 patients received an aspheric IOL in both eyes and 12 received spherical IOLs. The integrity of ocular functions w...
متن کاملEffect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses
PURPOSE To compare the effect of spherical aberration on optical quality in eyes with two different aspherical intraocular lenses. METHODS 120 eyes of 60 patients underwent phacoemulsification. In patients' eyes, an aberration-free IOL (Aspira-aA; Human Optics) or an aberration-correcting aspherical IOL (Tecnis ZCB00; Abott Medical Optics) was randomly implanted. After surgery, contrast sensi...
متن کاملQuality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision.
PURPOSE To compare ocular performance and quality of vision in pseudophakic eyes with an aspherical intraocular lens (IOL) or a conventional spherical IOL. SETTING Bretonneau University Hospital, Tours, France. METHODS Twenty patients (40 eyes) were randomly divided in 2 equal groups to bilaterally receive the aspherical Tecnis Z9000 IOL (AMO) or the spherical CeeOn Edge 911 IOL (AMO). Cont...
متن کاملHigher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics.
AIM To compare higher order aberrations in two aspherical intraocular lenses (IOLs): Akreos advanced optics (AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface (MC6125AS) with each other. METHODS Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberra...
متن کاملQualité de vision des patients porteurs d’un implant asphérique prolate après chirurgie de la cataracte Étude comparative de la vision des contrastes et des aberrations optiques
Purpose: To assess the quality of vision in pseudophakic patients with a prolate aspherical intraocular lens (IOL) compared to patients with a spherical IOL. Patients and methods: Twenty patients undergoing cataract surgery were divided into two groups according to the type of IOL: ten prolate aspherical IOLs (TECNIS Z9000, AMO, USA) and ten spherical IOLs (911 CeeOn Edge, AMO, USA). The integr...
متن کامل