The Normal Apex Cardiogram

نویسنده

  • LAWRENCE S. COHEN
چکیده

T HE apex cardiogram was described in 1878 by Marey.' With the exception of its utilization in the timing of the opening snap of the mitral valve 2 3 and in the identification of the third and fourth heart sounds,4-6 it has been used only infrequently as an aid in timing cardiac phenomena. Technical difficulties in its recording have obstructed its more universal application and, more particularly, its use in timing systolic events of the cardiac cycle. There is no general agreement about the meaning of the apex cardiogram. It is still argued whether the tracing represents the recording of lowfrequency vibrations of the precordium or of the actual movements of the heart.3 7-9 Furthermore, the normal configuration of the systolic wave of the apex cardiogram has not been determined with certainty. If a normal "systolic pattern" were established, deviation from this might be helpful in assessing certain pathophysiologic states. It is the purpose of this report to analyze the normal configuration of the systolic wave of the apex cardiogram by comparing the apex cardiogram with the simultaneous

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Normal Apex Cardiogram Its Temporal

T HE apex cardiogram was described in 1878 by Marey.' With the exception of its utilization in the timing of the opening snap of the mitral valve 2 3 and in the identification of the third and fourth heart sounds,4-6 it has been used only infrequently as an aid in timing cardiac phenomena. Technical difficulties in its recording have obstructed its more universal application and, more particula...

متن کامل

The Normal Apex

T HE apex cardiogram was described in 1878 by Marey.' With the exception of its utilization in the timing of the opening snap of the mitral valve 2 3 and in the identification of the third and fourth heart sounds,4-6 it has been used only infrequently as an aid in timing cardiac phenomena. Technical difficulties in its recording have obstructed its more universal application and, more particula...

متن کامل

Relation between apex cardiogram and changes in left ventricular pressure and dimension.

The relation between the apex cardiogram and changes in left ventricular pressure measured by micromanometer, and dimension measured by echocardiography, was studied in 12 normal subjects and 64 patients with heart disease. In 12 patients, the apex cardiogram was delayed with respect to simultaneous left ventricular pressure by 17 +/- 18 ms during the upstroke and 28 +/- 16 ms during the downst...

متن کامل

Time relation between apex cardiogram and left ventricular events using simultaneous high-fidelity tracings in man.

In 10 patients without left heart valvular disease and having normal function of the left ventricle, the left ventricular apex cardiogram with its first derivative (dA/dt), left ventricular pressure with its first derivative (dP/dt), aortic pressure, electrocardiogram, and phonocardiogram were reocrded simultaneously during cardiac catheterization. The apex cardiographic tracings were obtained ...

متن کامل

A Journal of the American Heart Association. Ballistocardiography Ii. the Normal Ballistocardiogram

In this study, the normal ballistocardiogram is interrelated with various cardiac events in order to establish the origin of its component waves. It is apparent that the ballistic F, G, H, I, J, K, L, M and N waves bear a definite relationship to known cardiac events, although in some cases the temporal positioning of the complexes is shifted by uncontrollable forms of distortion. When calculat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005