Comparative in vitro assessment of the primary stability of cementless press-fit acetabular cups.

نویسندگان

  • Bruno Olory
  • Eric Havet
  • Antoine Gabrion
  • Joël Vernois
  • Patrice Mertl
چکیده

Long-term stable osseointegration of porous-coated acetabular cups depends on bony ingrowth within their porous surface. For ingrowth to take place, one must ensure rigid initial fixation of the implant, by means of screws or by impaction or using a threaded ring. Primary stability is a prerequisite for long term stability through bony ingrowth. We tested several cups commonly used in our department to assess their primary stability. The study was done using synthetic EP-Dur polyurethane resin blocks (Bayer, Leverkusen, Germany). The blocks were fixed at a 45 degrees angle to the horizontal. They were subsequently reamed using the appropriate reamers and the cups tested were impacted into the resin blocks. Eleven 52-mm cups were tested. The pull out force necessary to extract each cup was measured. The pull-out strength ranged from 7.63 to 55.46 Nm. We noted that the closer the cup was to a hemisphere, the better was the initial stability. The contact zone was at the periphery, and the greater the contact was with the resin, the better was the stability. Micromovements exceeding 150 microns prevent any bony ingrowth in vivo. Solid osseointegration can thus only be achieved if movements between implant and bone can be prevented. Our study indicated that initial fixation is essentially peripheral and that those cups that demonstrated the highest pull-out values also had the best peripheral contact. Our observations suggest that the geometry of the cup is more important than its surface macrostructure in terms of primary stability. To achieve stable fixation, we recommend using an oversized cup with a flattened dome to allow maximum peripheral contact.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact sensitivity analysis of FE model of the pelvis with press-fit acetabular prosthesis

Introduction Lack of primary stability has been regarded as a major cause for implant loosening in total hip arthroplasty. For a cementless press-fit acetabular cup, primary stability is achieved by inserting an oversized component into an under-reamed acetabulum. Two features that result from the press-fitting process are – 1) pre-stress due to the difference in the radii of the cup and the re...

متن کامل

Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-...

متن کامل

Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?

BACKGROUND Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. METHODS The maximum tilting moment fo...

متن کامل

A novel method to assess primary stability of press-fit acetabular cups.

Initial stability is an essential prerequisite to achieve osseointegration of press-fit acetabular cups in total hip replacements. Most in vitro methods that assess cup stability do not reproduce physiological loading conditions and use simplified acetabular models with a spherical cavity. The aim of this study was to investigate the effect of bone density and acetabular geometry on cup stabili...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 70 1  شماره 

صفحات  -

تاریخ انتشار 2004