Influence of hydration status in normal subjects: fractional analysis of parameters of Tc-99m DTPA and Tc-99m MAG3 renography.
نویسندگان
چکیده
RATIONALE AND OBJECTIVES The purpose of this study was to evaluate the influence of hydration status upon renogram patterns and renal physiological parameters and clarify the differences between DTPA and MAG3 studies in normal volunteers. MATERIAL AND METHODS The study populations were 22 kidneys of 11 volunteers with no history of hypertension or renal disease with normal serum creatinine levels. They were 6 men and 5 women aged from 24 to 48 yrs (mean age: 33.4 yrs). Renal scintigraphies with both 185 MBq (5 mCi) of Tc-99m DTPA and Tc-99m MAG3 were performed after dehydration (urine specific gravity > 1.025) and adequate hydration (urine specific gravity < 1.010) in each subject at least with a 5-7-day interval. Renograms were generated from the whole kidney and cortical ROIs. We analyzed the clearance, renogram pattern, mean transit time, time to maximum activity, time from maximum activity to half activity, and residual cortical activity. Paired t-test and Wilcoxon signed rank test were used as statistical analysis methods. Statistical analysis was considered significant at p < 0.05. RESULTS In the dehydrated state, with Tc-99m DTPA and whole kidney ROI, parameters such as time to maximum activity, time from maximum activity to half activity, residual cortical activity, and mean transit time were delayed as compared to parameters in the adequately hydrated state, but the clearance was not changed. With the cortical ROI, the changes of parameters due to dehydration were partially offset. There were insignificant differences between most parameters of Tc-99m DTPA and Tc-99m MAG3 with the whole kidney and cortical ROIs. CONCLUSIONS Dehydration may bring about a false positive curve pattern on renograms which can be prevented or minimized by using the cortical ROI. There were insignificant differences between most parameters of Tc-99m DTPA and Tc-99m MAG3.
منابع مشابه
Administration of 99mTc-DTPA in combination with doxorubicin alters the radiopharmaceutical biodistribution in rats
Introduction:Diethylenetriaminepentaacetic acid (DTPA) is a chelating agent used as a radiopharmaceutical compound, 99mTc-DTPA, for renography. Doxorubicin (DOX) on the other hand is an effective chemotherapy drug used to treat a variety of solid malignancies. Both 99mTc-DTPA and DOX may be used in close succession in patients undergoing DOX based chemoth...
متن کاملComparison of Tc-99m Ethylenedicysteine (Tc-99m EC) with Tc-99m DPTA in evaluation of renal disease [Persian]
Tc-99m-EC is a new renal radiopharmaceutical introduced as an alternative for Tc-99m MAG3. Twenty-three normal volunteers and patients in different .stages of renal disease were evaluated with Te-99m EC and Tc-99m DTPA. The mean initial uptake of EC was significantly higher as compared to DTPA. There was a high correlation between rectangular and hand-drawn ROls for kidney and background,...
متن کاملDynamic and static small-animal SPECT in rats for monitoring renal function after 177Lu-labeled Tyr3-octreotate radionuclide therapy.
UNLABELLED High kidney radiation doses during clinical peptide receptor radionuclide therapy (PRRT) with β-particle-emitting radiolabeled somatostatin analogs will lead to renal failure several months after treatment, urging the coinfusion of the cationic amino acids lysine and arginine to reduce the renal radiation dose. In rat PRRT studies, renal protection by the coadministration of lysine w...
متن کاملAcetazolamide assisted Tc-99m MAG3 renography to assess renal blood flow reserve.
OBJECTIVE The present study examines whether or not baseline and acetazolamide (ACZ) Tc-99m MAG3 renography can assess renal blood flow reserve. METHODS Renography proceeded for 50 min after sequential injections of 370 MBq Tc-99m MAG3 for baseline renography and 10 min after a 1,000 mg injection of ACZ for ACZ renography. Effective renal plasma flow of renal cortex (cERPF) in each kidney and...
متن کاملQuantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic
Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 19 1 شماره
صفحات -
تاریخ انتشار 2005