The prediction of ICD therapy in multicenter automatic defibrillator implantation trial (MADIT) II like patients: a retrospective analysis

نویسندگان

  • Marco Budeus
  • Nico Reinsch
  • Heinrich Wieneke
  • Stefan Sack
  • Raimund Erbel
چکیده

OBJECTIVES MADIT II like patients have not been compared to patients without an electrophysiological study, patients in whom ventricular tachycardia or fibrillation were induced in an electrophysiological study (EPS) and patients without an inducibility in EPS in one study. BACKGROUND The multicenter automatic defibrillator implantation trial (MADIT) II showed a benefit of ICD implantation in patients with ischemic heart disease. METHODS We performed a retrospective analysis in 93 patients with an ischemic heart disease and an ejection fraction </=30% who had an ICD implanted with a follow-up at least an 18 months. Patients were divided into 3 groups according to the primary indication for ICD implantation: without EPS (group I), patients in whom ventricular tachycardia or fibrillation were inducible in EPS (group II) or patients without an inducibility in EPS (group III). RESULTS During the mean follow-up of 32.9 +/- 16.1 months 289 appropriate ICD therapies and 10 deaths occurred. The incidence of appropriate ICD therapies did not differ significantly between the groups (group I 40%, group II 54% and group III 48% of patients). We found in group II a higher risk of appropriate ICD therapies with occurrence of a specific constellation of EPS values. These patients showed a 15-fold risk (P = 0.005) of an appropriate ICD therapy. Furthermore a brain natriuretic peptide value of 265 pg/ml also predicted an appropriate ICD therapy with a 3.5-fold risk (P = 0.017). CONCLUSION In the present retrospective study the results of MADIT II were affirmed in the case of incidence of ventricular arrhythmias in patients with an EF < 30% and coronary heart disease. The prediction of an appropriate ICD therapy with EPS was only achieved in patients with inducibility in the EPS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Primary Prevention of Fatal Ventricular Arrhythmias With Implantable Cardioverter-Defibrillator Therapy – An Analysis of Implications Based on MADIT II Criteria

AIMS The primary aim of this retrospective study was to determine the proportion of patients with myocardial infarction (MI) who fulfil the criteria of the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II and the implications of MADIT II criteria in practice. METHODS We performed a retrospective analysis of three hundred and ninety four admissions to the Coronary Care Unit (C...

متن کامل

Are the MADIT II criteria for ICD implantation appropriate for Japanese patients?

BACKGROUND The Multicenter Automatic Defibrillator Implantation Trial (MADIT) II investigators concluded that prophylactic use of an implantable cardioverter defibrillator (ICD) improved survival in patients with prior myocardial infarction (MI) and reduced the left ventricular ejection fraction (LVEF). However, it is unclear whether MADIT II criteria for ICD implantation are appropriate for Ja...

متن کامل

Long-Term Survival of Multicenter Automatic Defibrillator Implantation Trial (MADIT) II-Eligible Patients in Taiwan.

BACKGROUND he Multicenter Automatic Defibrillator Implantation Trial (MADIT) II showed that use of a prophylactic implantable cardioverter defibrillator (ICD) improved the survival of patients with poor left ventricular ejection fraction after myocardial infarction. The major concerns about primary ICD prevention in Asian countries are the long-term survival and the incidence of sudden cardiac ...

متن کامل

Mortality and predictors of appropriate implantable cardioverter defibrillator therapy in Japanese patients with Multicenter Automatic Defibrillator Implantation Trial II criteria

BACKGROUND Data regarding long-term mortality and factors influencing appropriate therapies in Japanese patients with implantable cardioverter defibrillators (ICD), who satisfy the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) criteria for primary prevention, remain scarce. METHODS A total of 118 consecutive patients who underwent ICD implantation without any prior vent...

متن کامل

Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients.

UNLABELLED In the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II, implantable cardioverter-defibrillator (ICD)-randomized patients underwent electrophysiologic testing. Both inducible and noninducible patients received an ICD. We correlated inducibility with the occurrence of subsequent ventricular tachycardia (VT) or ventricular fibrillation (VF). Intracardiac ICD electrogra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008