Arterial elasticity imaging: comparison of finite-element analysis models with high-resolution ultrasound speckle tracking
نویسندگان
چکیده
BACKGROUND The nonlinear mechanical properties of internal organs and tissues may be measured with unparalleled precision using ultrasound imaging with phase-sensitive speckle tracking. The many potential applications of this important noninvasive diagnostic approach include measurement of arterial stiffness, which is associated with numerous major disease processes. The accuracy of previous ultrasound measurements of arterial stiffness and vascular elasticity has been limited by the relatively low strain of nonlinear structures under normal physiologic pressure and the measurement assumption that the effect of the surrounding tissue modulus might be ignored in both physiologic and pressure equalized conditions. METHODS This study performed high-resolution ultrasound imaging of the brachial artery in a healthy adult subject under normal physiologic pressure and the use of external pressure (pressure equalization) to increase strain. These ultrasound results were compared to measurements of arterial strain as determined by finite-element analysis models with and without a surrounding tissue, which was represented by homogenous material with fixed elastic modulus. RESULTS Use of the pressure equalization technique during imaging resulted in average strain values of 26% and 18% at the top and sides, respectively, compared to 5% and 2%, at the top and sides, respectively, under physiologic pressure. In the artery model that included surrounding tissue, strain was 19% and 16% under pressure equalization versus 9% and 13% at the top and sides, respectively, under physiologic pressure. The model without surrounding tissue had slightly higher levels of strain under physiologic pressure compared to the other model, but the resulting strain values under pressure equalization were > 60% and did not correspond to experimental values. CONCLUSIONS Since pressure equalization may increase the dynamic range of strain imaging, the effect of the surrounding tissue on strain should be incorporated into models of arterial strain, particularly when the pressure equalization technique is used.
منابع مشابه
Venous elastography: validation of a novel high-resolution ultrasound method for measuring vein compliance using finite element analysis.
Ultrasonography for the noninvasive assessment of tissue properties has enjoyed widespread success. With the growing emphasis in recent years on arteriovenous fistulae (AVFs) for dialysis vascular access in patients with end-stage renal disease, and on reducing AVF failures, there is increasing interest in ultrasound for the preoperative evaluation of the mechanical and elastic properties of ar...
متن کاملHigh-resolution ultrasound elasticity imaging to evaluate dialysis fistula stenosis.
Accurate, noninvasive characterization of arterial wall mechanics and detection of fibrotic vascular lesions could vastly improve the ability to predict patient response to local treatments such as angioplasty. Current imaging and other techniques for determining wall compliance rely on imprecise or indirect estimates of wall motion. This study used high-resolution ultrasound imaging with phase...
متن کاملTemperature Mapping Using Ultrasound Digital Images
Introduction: The success of hyperthermia depends on the accuracy of the temperature monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes were determined by computing the speckle displacement in the ultrasound digital images. Speckle tracking algorithm was used to compute the displacement. Materials and Methods: The experiment was perf...
متن کاملICMA: an integrated cardiac modeling and analysis platform
UNLABELLED ICMA, a software framework to create 3D finite element models of the left ventricle from cardiac ultrasound or magnetic resonance imaging (MRI) data, has been made available as an open-source code. The framework is hardware vendor independent and uses speckle tracking (endocardial border detection) on ultrasound (MRI) imaging data in the form of DICOM. Standard American Heart Associa...
متن کاملUltrasound Speckle Tracking For Strain Estimation
This paper presents an alternative to Elastography by speckle tracking ultrasonic frames quantifying both motion and strain. We combine two similarity measures for varying echographic content including displacement processing, with interframe and trajectory performance measured on extensive synthetic and in vitro data.
متن کامل