Interference in glucose and other clinical chemistry assays by thiocyanate and cyanide in a patient treated with nitroprusside.
نویسندگان
چکیده
A 3-year-old patient treated with nitroprusside for congestive heart failure had 6.5 mmol/L thiocyanate (toxic, >1.5 mmol/L) and 110 micromol/L cyanide (toxic, >5 micromol/L) present in her blood. At this time a whole-blood glucose concentration assayed on the Nova Stat Profile 5 Plus (Stat Profile) was 25.1 mmol/L. Plasma from that specimen analyzed on a Kodak Ektachem 700 analyzer (E700) indicated 5.2 mmol/L glucose. We investigated the potential interference of dissolved thiocyanate or cyanide on glucose and other routine assays. Toxic concentrations of thiocyanate increased Stat Profile glucose values and E700 total calcium, chloride, and creatinine values. Stat Profile ionized calcium values were decreased by toxic concentrations of thiocyanate. Cyanide (100 micromol/L) decreased alanine aminotransferase activity measured on the E700. Interference with the Stat Profile glucose assay may have been caused by thiocyanate oxidation at the glucose electrode.
منابع مشابه
Some aspects of sodium nitroprusside reaction with human erythrocytes.
Sodium nitroprusside is an excellent agent for lowering blood pressure in hypertensive emergencies, for producing controlled hypotension during anesthesia, and for treating acute myocardial infarction and chronic heart failure. Toxic effects of this drug have been reported and above-normal cyanide and thiocyanate concentrations have been observed in the blood of a small proportion of subjects r...
متن کاملInterference in laboratory tests
Interference in clinical laboratory testing can create discrepancies in test results which can lead to patient harm. In clinical chemistry, interference is defined as a cause of medically significant difference in the measurand test result due to another component or property of the sample. Interference by endogenous and exogenous substances with assays for clinical analytes is a common prob...
متن کاملSimple method for determination of thiocyanate in urine.
BACKGROUND It would be useful to develop a simple kit method for determination of thiocyanate in urine, which could be used to monitor cyanide overload in cassava-consuming populations. METHODS The method was based on the quantitative oxidation of thiocyanate in acid permanganate at room temperature in a closed vial with liberation of HCN, which reacted with a picrate paper. For semiquantitat...
متن کاملSimultaneous Determination of Thiocyanate and Oxalate in Urine using a Carbon Ionic Liquid Electrode Modified with TiO2-Fe Nanoparticles
A carbon ionic liquid electrode (CILE) modified with TiO2-Fe nanoparticles was constructed by incorporating TiO2-Fe nanoparticles into the paste matrix. Under the optimized experimental conditions, using differential pulse voltammetry (DPV), the oxidation of thiocyanate and oxalate were occurred at potentials of 0.740 V and 1.010 V, respectively, at the surface of the modi...
متن کاملCyanide and thiocyanate concentrations following sodium nitroprusside infusion in man.
Twenty-six patients, receiving an infusion of sodium nitroprusside (SNP) during surgery, had considerable increases in both red cell and plasma cyanide concentration, but only small changes in plasma thiocyanate concentration. There was a linear relationship between both plasma and RBC cyanide concentrations and the total dose of SNP. The expired cyanide concentration followed the changes in th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 3 شماره
صفحات -
تاریخ انتشار 1996