Mechanical influence of thread pitch on orthodontic mini-implant stability.

نویسندگان

  • Amanda Carneiro da Cunha
  • Amanda Osório Ayres de Freitas
  • Mariana Marquezan
  • Lincoln Issamu Nojima
چکیده

The aim of this study was to evaluate the effect of pitch distance on the primary stability (PS) of orthodontic mini-implants (MIs) in artificial bone. Twenty experimental MIs were allocated to two groups, according to their geometric design: G1 (30o X 0.6 mm) and G2 (45o X 0.8 mm), and inserted into artificial bone of different densities: D1 (0.32 g/cm3) and D2 (0.64 g/cm3). The maximum insertion torque (IT) and removal torque (RT) values were recorded in N.cm. Loss of torque (LT) values were obtained by calculating the difference between the IT and RT. MI mobility was measured by means of a Periotest assessment. Normality and homogeneity were determined by means of the Kolmogorov-Smirnov and Shapiro-Wilk tests, respectively. A two-way ANOVA was used to detect differences between the mini-implant design and density factors. The ANOVA/Tukey tests were used to determine the intergroup difference. Higher IT values were observed for G2 (p ≤ 0.05) in D2. No statistical difference for RT was observed between the groups, whereas G2 presented higher values only for LT (p ≤ 0.05). The Periotest values (PTV) were higher for G1, in comparison with G2, in D1. G1 presented better PS in D2 (IT, RT and LT), whereas G2 was found to be more stable in D1, after evaluation with Periotest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

Morphological evaluation of the active tip of six types of orthodontic mini-implants.

OBJECTIVE To morphologically evaluate the active tip of six different types of self-drilling mini-implants for orthodontic anchorage. METHODS Images of the active tips of the mini-implants were obtained with a Zeiss optical microscope Stemi 200-C, with magnification of 1.6X. The images of the surface were viewed with the Axio Vision program (Zeiss, Jena, Germany) to calculate linear and angul...

متن کامل

Effect of Thread Design of Orthodontics Mini Implants on Their Stability - A Pilot Study

ObjectivesThis FEM study was conducted in order to investigate the effect of thread design of an orthodontic mini-implant on primary stability and strain pattern and magnitude in the surrounding bone structure during orthodontic loading. Materials and MethodsThe mini-implants by six different manufacturers such as Aarhus Mini-Implant (American Orthodontics), AbsoAnchor (Dentos), Dual-Top (Jeil ...

متن کامل

Influence of Thread Pitch, Helix Angle, and Compactness on Micromotion of Immediately Loaded Implants in Three Types of Bone Quality: A Three-Dimensional Finite Element Analysis

This study investigated the influence of thread pitch, helix angle, and compactness on micromotion in immediately loaded implants in bone of varying density (D2, D3, and D4). Five models of the three-dimensional finite element (0.8 mm pitch, 1.6 mm pitch, 2.4 mm pitch, double-threaded, and triple-threaded implants) in three types of bone were created using Pro/E, Hypermesh, and ABAQUS software....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2015