The role of ultrasound imaging in the diagnosis of breast implant rupture: a prospective study.

نویسندگان

  • J C Liston
  • C M Malata
  • S Varma
  • M Scott
  • D T Sharpe
چکیده

Breast ultrasound to assess possible implant rupture was performed on 24 consecutive patients (43 breasts) by the same radiologist immediately before revisional breast implant surgery. Comparison of the clinical, ultrasound and operative findings showed ultrasound to be three times as sensitive as clinical judgement in predicting implant rupture. The sensitivity of ultrasound in predicting impaired implant integrity was 70% (versus 23% for clinical examination) with a specificity of 96%. The ultrasound features indicating leakage are outlined later. The positive predictive value of an abnormal scan was 90% and that of a normal scan 87%. It is concluded that breast ultrasound is a simple, quick, non-invasive method which contributes significantly to the assessment of patients with suspected breast implant rupture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging features of estrogen-negative breast cancers: a correlation study with human epidermal growth factor type II overexpression

Background: Estrogen-negative breast cancers have different clinical course, prognostic features and treatment response in comparison to estrogen receptor-positive (ER-positive) breast cancers. Human epidermal growth factor receptor 2 (HER2) oncoprotein has found to have a pivotal role in natural cell growth and cell division and is suggested to be directly related to tumor invasiveness in brea...

متن کامل

Correlation between MRI results and intraoperative findings in patients with silicone breast implants

BACKGROUND Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. METHODS Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the pati...

متن کامل

Onm-1: Imaging in Female Infertility

The role of imaging in female infertility has undergone a revolution over the past few decades .Sonography plays an integral role in the evaluation of gynecologic disease. It can determine the organ or site of abnormality and provide a diagnosis or short differential in the vast majority of patients. Both the transabdominal and transvaginal approaches are now well –established techniques for as...

متن کامل

Pregnancy in Non-Communicating Rudimentary Horn of A Unicornuate Uterus

Background: Diagnosis and management of pre-rupture stage of the pregnant horn are difficult and usually missed on a routine ultrasound scan. Furthermore, most cases are detected after rupture of pregnant horn. Case: We presented a 28-year-oldG2 L1 woman with diagnosis of RHP at 14 weeks of gestation. She was initially diagnosed with a normal intrauterine pregnancy, whereas a pregnancy in a rig...

متن کامل

Bedside Ultrasonography for Early Diagnosis of Occult Radial Head Fractures in Emergency Room: A CTComparative Diagnostic Study

Background: Some of the Mason type I fractures cannot be detected on early radiographic images. These occultfractures are considered as a diagnostic challenge for physicians. Our aim was to determine the value of bedsideultrasonography for the detection of Mason I radial head fractures that are non-visible in early X-ray’s.Methods: A prospective blind single-center diagnostic study was conducte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of plastic surgery

دوره 47 7  شماره 

صفحات  -

تاریخ انتشار 1994