Double-access-port endotracheal tube for selective lung ventilation in pediatric patients.
نویسندگان
چکیده
To the Editor-Recent developments of thoracoscopic surgical instmments and techniques have increased the demand for selective lung ventilation in younger children. Because the use of pediatric doublelumen endotracheal tubes' is limited, this is conventionally accomplished by blocking the required bronchus with a Fogarty embolectomy catheter' or with a pulmonary artery catheter.' In most reported cases, a bronchial blocker is placed blindly or through a rigid bronchoscope before tracheal intubation. Appropriate positioning of the blocker is subsequently confirmed by fiberoptic bronchoscopy, aus cultation, or chest radiography. However, these methods entail two major disadvantages. First, hypoxemia can occur during the placement of a blocker. Second, when dislocation of the blocker occurs during surgery, repositioning is difficult. To overcome these problems, we fabricated a double-access-port endotracheal tube by combining two conventional Murphy-type tubes for the use of one-lung ventilation in pediatric patients. For the equipment preparation (fig. l), a tracheal tube of the appropriate inner diameter (ID) (uncuffed or cuffed) is selected (inner tube). Another tube of ID within 0.5 mm larger than the outer diameter (OD) of the inner tube is prepared (outer tube). A side port is made at a position approximately 8 cm from the proximal end of the inner tube. The distal three fifths of the outer tube is cut off, and a side port slightly larger than the OD of the inner tube is also made at 2 or 3 cm proximal from the distal cut end. These side holes can be cut simply with scissors in the folded tubes and with an appropriate surgical instrument, such as an aorta punch. The inner tube then protrudes from the side port through the distal cut end of the outer tube, such that the side port of the inner tube is placed within the outer tube lumen. To facilitate insertion, water lubrication is helpful. For a cuffed inner tube, an inverse insertion is recommended to avoid possible cuff damage. A tight air seal can be easily achieved by taping if an air leak is found at the bifurcation of the tubes. The taping can also prevent slippage of the tubes that could result in an airway obstruction. The 15-mm connector of the outer tube is sealed with a silted rubber cap so that it can be used as an access port for a blocking catheter. To ensure airtightness during the blocker operation, we insert a shortened catheter sheath into this rubber cap. This tube provides independent access for blocker operations and ventilation both. Thus, sufficient ventilation can be obtained during the
منابع مشابه
[Selective lobar blockade with a Coopdech blocker combined with a double-lumen endotracheal tube for lung metastases resection by laser].
In recent years, laser resection of lung metastases has been established as the standard procedure worldwide. To avoid airway fire, it is necessary to collapse the surgical lung. The selective lobar bronchial blockade is a technique that allows one-lung ventilation while the operated lobe is collapsed in patients with previous pulmonary resection requiring subsequent resection or with limited p...
متن کاملSelective bilateral bronchial intubation for large, acquired tracheoesophageal fistula.
The anesthetic management of patients undergoing tracheoesophageal fistula repair often involves lung separation, usually selective bronchial intubation with a double-lumen endotracheal tube. However, in patients with airway fistulas arising below the tracheal lumen, selective lung ventilation and separation may require unusual methods of airway management. In the patient described in this repo...
متن کاملImplantable Port Devices, Complications and outcome in Pediatric Cancer, a Retrospective Study
Abstract Background Peripheral blood vessels, due to availability are used for many years in cancer patients, however in patients with potentially harmful drugs to skin (vesicant drugs) or difficult accessibility to vessels, the use of implantable port (totally implantable venous access port-TIVAP)devices with central vascular access are important. ...
متن کاملClinical review: Independent lung ventilation in critical care
Independent lung ventilation (ILV) can be classified into anatomical and physiological lung separation. It requires either endobronchial blockade or double-lumen endotracheal tube intubation. Endobronchial blockade or selective double-lumen tube ventilation may necessitate temporary one lung ventilation. Anatomical lung separation isolates a diseased lung from contaminating the non-diseased lun...
متن کاملAcoustic monitoring of double-lumen ventilated lungs for the detection of selective unilateral lung ventilation.
One-lung intubation (OLI) is among the most common complications of endotracheal intubation. None of the monitoring tools now available has proved effective for its early detection. In this study we investigated the efficacy of acoustic analysis for the detection of OLI. We collected lung sounds from 11 patients undergoing thoracic surgery requiring the placement of a double-lumen tube. Recordi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 93 1 شماره
صفحات -
تاریخ انتشار 2000