Evaluation of Bladder Diary Parameters Based on Correlation with the Volume at Strong Desire to Void in Filling Cystometry

نویسندگان

  • Sheng-Mou Hsiao
  • Chin-Fen Hsiao
  • Chi-Hau Chen
  • Ting-Chen Chang
  • Wen-Yih Wu
  • Ho-Hsiung Lin
چکیده

Accurate assessment of patient bladder capacity is important in determining the proper initial treatment for lower urinary tract dysfunctions and as well as for monitoring therapeutic outcomes. However, urodynamic study is an invasive procedure. Thus, it is important to find a surrogate for invasive urodynamic study, and the aim of this study is to identify the parameter from patient-recorded bladder diary that is best correlated to the volume at strong desire to void (VSD) derived from urodynamic studies. A total of 900 women who underwent urodynamic studies at a university hospital between January 2009 and December 2011. Correlation between bladder diary parameters and VSD was investigated by Spearman rank-correlation coefficient. Days 1 to 3 average maximum daytime voided volumes excluding the first morning void (DVVmaxavg) (mean 263 ml) had the highest correlation with VSD (mean 261 ml; ρ = 0.51, p<0.001). The predictive value of VSD was 146+0.44 × DVVmaxavg. The days 1, 2, and 3 daytime maximum voided volumes excluding the first morning void (DVVmax) were all significantly associated with VSD and had similar mean volumes (ρ = 0.43-0.46, all p<0.001). DVVmaxavg had the highest area under the receiver operating characteristic curve (0.75; 95% confidence interval = 0.72-0.78) for predicting bladder oversensitivity. The threshold of DVVmaxavg <250 ml had good predictive value for detecting bladder oversensitivity (sensitivity 70.9%; specificity 65.8%), and day 1 DVVmax <250 ml had similar sensitivity (70.6%) and specificity (59.1%). Besides, the correlation coefficients (ρ) between day 1, day 2 and day 3 DVVmax and DVVmaxavg were good with a range of 0.70-0.89. In conclusion, DVVmaxavg was the bladder diary parameter best correlated with VSD. DVVmaxavg and day 1 DVVmax may be useful in screening for bladder oversensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of urodynamic filling sensation at weekly interval in healthy volunteers and in women with detrusor overactivity.

AIMS To evaluate the reproducibility of bladder sensation during standardized filling cystometry in female volunteers and overactive bladder (OAB) patients, repeated with weekly interval. METHODS We recruited 13 female nulliparous volunteers (age 21-47) and 17 female patients with OAB between (age 18-72). They participated in three investigation periods, each separated by 7 days to assess rep...

متن کامل

Bladder function after spinal anesthesia for cesarean section: an urodynamic evaluation.

BACKGROUND This study evaluates the effects of spinal anesthesia with hyperbaric bupivacaine plus sufentanil on bladder function in women undergoing cesarean section. SUBJECTS AND METHODS Thirty caucasian healthy pregnants scheduled for elective Cesarean section under spinal anesthesia performed with hyperbaric bupivacaine plus sufentanil were enrolled. Filling cystometry, proprioceptive blad...

متن کامل

Effect of aging on urodynamic parameters in women with stress urinary incontinence

PURPOSE Stress urinary incontinence (SUI) is one of the most common lower urinary tract symptoms in women. We analyzed age-associated changes in urodynamic parameters in women with SUI. MATERIALS AND METHODS We analyzed the urodynamic study (UDS) results of patients with urodynamically proven SUI between March 2008 and July 2014. In uroflowmetry, maximal flow rate (Qmax), time to Qmax, voided...

متن کامل

The effect of posture and repetition on urodynamic parameters: A prospective randomized study

PURPOSE To evaluate the effect of posture and repetition of filling cystometry on urodynamic parameters. MATERIALS AND METHODS Seventy-one men with benign prostatic hyperplasia participated in a urodynamic study between September 2015 and August 2016 and were randomly assigned to a supine to supine (group SS, n=16), erect to erect (group EE, n=16), supine to erect (group SE, n=19) or erect to...

متن کامل

[Diagnostic values and limitations of conventional urodynamic studies (uroflowmetry.residual urine measurement.cystometry) in benign prostatic hypertrophy].

PURPOSE AND METHODS Diagnostic values and limitation of conventional urodynamic study (UDS) were assessed in 380 patients with benign prostatic hypertrophy (BPH), in terms of uroflowmetry, measurement of postvoid residual urine and cystometry. RESULTS Maximum and average flow rate on uroflowmetry improved with increasing voided volume. Neither maximum nor average flow rate correlated with siz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013