Comparison of Manual Keratometer with Autokeratometer

نویسندگان

  • Reshma Ramakrishnan
  • Abhijit Naik
چکیده

The study was done to compare the corneal curvature readings obtained by Baush and Lomb manual keratometer with that of Nidek autokeratometer ARK-30 to find if either was superior to the other. Curvature of central 3mm corneal zone was measured in horizontal and vertical meridian with Bausch and Lomb manual keratometer and Nidek autokeratometer ARK30 in 67 eyes of 52 patients between the age group 53 and 75. The readings were correlated and intraclass correlation (ICC) was calculated with 95% confidence limit. Mean +/one Standard Deviation of differences between two readings (manual versus auto) was calculated. The autokeratometric values were predicted from manual readings using linear regression model. Vertical and horizontal readings obtained by two methods were comparable. Differences in values obtained by two methods were statistically insignificant. The corneal curvature readings obtained by Bausch and Lomb manual keratometer were comparable with that obtained by Nidek autokeratometer ARK-30.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the corneal curvatures obtained from three different keratometers.

INTRODUCTION Keratometry forms an important component of the biometry for a calculation of the intraocular lens power and selecting a contact lens' parameters. OBJECTIVE To investigate the agreement between three different keratometers commonly used in an ophthalmology clinic. MATERIALS AND METHODS In this prospective study, keratometry was performed using an IOL Master (IM), a manual kerat...

متن کامل

Verifying the calibration of a manual one-position keratometer

A keratometer, also known as an ophthalmometer, is a diagnostic instrument for measuring the curvature of the anterior surface of the cornea, which is used to assess the amount and axis of astigmatism. A very popular and reliable type of manual, one-position keratometer (commonly known as a Bausch and Lombtype keratometer) is shown in Figure 1. Although this type of keratometer rarely goes out ...

متن کامل

Which Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses?

PURPOSE To evaluate the accuracy of preoperative keratometers used in cataract surgery with toric intraocular lens (IOL). METHODS Twenty-five eyes received an AcrySof toric IOL implantation. Four different keratometric methods, a manual keratometer, an IOL master, a Pentacam and an auto keratometer, were performed preoperatively in order to evaluate preexisting corneal astigmatism. Difference...

متن کامل

Effectiveness and confounding factors of penetrating astigmatic keratotomy in clinical practice

RATIONALE Penetrating astigmatic keratotomy (penetrating AK) is a well-known method to correct corneal astigmatism but rarely be performed nowadays. This article reevaluated the clinical effectiveness and confounding factors of penetrating AK. PATIENT CONCERNS Penetrating AK has been introduced to serve as one alternative operation for astigmatism correction, and is thought to have the potent...

متن کامل

Comparison of videokeratoscope and autokeratometer measurements on ellipsoid surfaces and human corneas.

BACKGROUND Various studies have compared the accuracy and repeatability of autokeratometers and videokeratoscopes using calibrated convex surfaces. We investigate the agreement between the Topcon KR-3500 autokeratometer and the EyeSys videokeratoscope on human corneas and calibrated convex surfaces. METHODS Measurements were obtained from 30 convex ellipsoidal buttons and 20 right eyes of 20 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014