Effect of Technetium-99m on lodine-131 Thyroid Uptake Measurements
نویسنده
چکیده
Following administration of 2.5-5.0 mCi f 9mTc]pertechnetate, several hundred microcuries may be present in the necks of hyperthyroid patients after 6 hr. Coincidence summing of Tc-99m photons may disturb 1-131 uptake measurements in such patients if an oral diagnostic dose of 1-131 is administered immediately after completion of a f 9mTc]pertechnetate scintigram. Using a lower discriminator level of 300 keV, false increases of 10%-50% may occur at 6 hr. The 24-hr uptake is also affected if an 1-131 predose measurement is performed after administration of the Tc-99m dose. The authors have shown that these errors may be prevented by using a 1-mm lead filter in front of the scintillation detector. The attenuation of Tc-99m photons by the filter effectively eliminates summation pulses while it reduces the 1-131 countrate by approximately 28%.
منابع مشابه
Inaccuracy of Thyroid to Background Uptake Ratio in Evaluating Technetium-99m-pertechnetate Thyroid Uptake and Establishing an Improved Algorithm
Objective(s): The aim of this study was to explore the accuracy of thyroid to background uptake ratio (UR) in the evaluation of 99mTc-pertechnetate thyroid uptake (TcTU) and establishment of an improved algorithm. Methods: This study was conducted on the thyroid images of 322 patients with thyroid diseases and 67 controls. For the purpos...
متن کاملValue of technetium scintigraphy and iodine uptake measurement during follow-up of differentiated thyroid cancer.
UNLABELLED Measurement of serum thyroglobulin (Tg) levels and I-131 whole body scintigraphy (WBS) are used in the follow-up of patients with differentiated thyroid cancer (DTC). This study was designed to evaluate the significance of persistent I-131 uptake in the thyroid bed in patients with DTC following surgery and/or radioactive iodine ablation. Tc-99m thyroid scintigraphy (TS) and I-131 th...
متن کاملA false-positive I-131 finding of duodenum diverticulum in thyroid cancer evaluation by SPECT/CT
RATIONALE Iodine-131 (I-131) is a sensitive marker for the detection of differentiated thyroid cancer (DTC). I-131 whole-body scintigraphy (WBS) has been used widely in evaluation of DTC patient. However, I-131 WBS exists many false-positive uptake of I-131 because radioiodine uptake can also be seen in healthy tissue or in a variety of benign and malignant non-thyroidal tumors. PATIENT CONCE...
متن کاملComparison of Technetium-99m MAG3TM and lodine-131 OIH ERPF Results Using the Camera Technique
Recent studies have suggested that technetium-99m (19mTc) MAG3 can be substituted for iodine-131 ( 131 I) OIH, with better image quality and lower radiation dose. This study compares the two radiopharmaceuticals for effective renal plasma flow (ERPF) results using only the camera method. Twenty patients with varying degrees of renal impairment were studied. In 13 of these patients, direct compa...
متن کاملComparison of Technetium-99m MAG3TM and lodine-131 OIH ERPF Results Using the Camera Technique
Recent studies have suggested that technetium-99m (19mTc) MAG3 can be substituted for iodine-131 ( 131 I) OIH, with better image quality and lower radiation dose. This study compares the two radiopharmaceuticals for effective renal plasma flow (ERPF) results using only the camera method. Twenty patients with varying degrees of renal impairment were studied. In 13 of these patients, direct compa...
متن کامل