Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs.

نویسندگان

  • S L Hale
  • K J Alker
  • R A Kloner
چکیده

Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nuclides. Simultaneous blood flow measurements with two nuclide-labeled and two colored microspheres were performed after coronary occlusion in dogs. Both techniques show a within-method correlation of r greater than 0.98. Duplicate variability for paired RMBF values in 80 samples was 8.7 +/- 0.1% when computed with radioactive microspheres and 13.2 +/- 1.8% when computed with colored microspheres. There was a good correlation in the measurement of RMBF between the radioactive- and colored-microsphere methods (r = 0.98). The best-fitting linear regression line was expressed by the formula: Colored-microsphere RMBF = 1.11 (radioactive-microsphere RMBF)-0.02. When measured by colored microspheres, RMBF was approximately 8% higher than when computed with radioactive microspheres for blood flow values of 0-2 ml/min/g. When blood flow was increased pharmacologically to levels of 2-7.5 ml/min/g, colored microspheres yielded blood flow values 39% higher than the values computed by radioactive microspheres. We conclude that the nonradioactive, colored-microsphere method correlates with the radioactive technique, but at high flows, it yields values greater than those obtained with radioactive microspheres.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of pulpal blood flow in dogs with nonradioactive colored microspheres.

The viability of dental pulp depends largely on regional blood flow, as in other organs. Measurement of absolute pulpal blood flow (PBF) and comparisons with blood flow in other organs allow the prediction of microvascular regulation in dental pulp. In previous studies, PBF was measured in dogs mainly with radioactive microspheres. However, this established technique is inaccessible to many inv...

متن کامل

Measurement of regional myocardial blood flow with multiple colored microspheres.

BACKGROUND The use of radioactive microspheres (RM) for the measurement of regional myocardial blood flow (RMBF) is limited and inaccessible to many investigators due to radiation safety concerns and radioactive waste disposal problems. Therefore, a new method for the measurement of RMBF using colored microspheres (CM) was developed. METHODS AND RESULTS Polystyrene spheres (diameter, 15 +/- 0...

متن کامل

Measurement of myocardial blood flow by ultrafast computed tomography.

Myocardial blood flow was analyzed by radioisotope-labeled microspheres and ultrafast computed tomography (CT) in 16 closed-chest, anesthetized dogs. The first set of 10 dogs had CT and microsphere measurements before and after chromonar-induced increases in myocardial blood flow. A second set of six dogs had flows measured at control and during temporary reductions in regional flow produced by...

متن کامل

Quantification of regional myocardial blood flow in vivo with H215O.

Using H215O (half-life = 2.1 min) we demonstrated that a modification of the tissue autoradiographic approach permitted quantitation of myocardial blood flow in open-chest dogs by direct assay of myocardial tissue and that noninvasive estimation with positron-emission tomography (PET) delineated relative myocardial blood flow in intact dogs. In open-chest anesthetized dogs, the single-pass extr...

متن کامل

Highly Localized In Vivo Measurement of Myocardial Perfusion with Avalanche Radiation Detectors RONALD

A problem in accurately measuring regional myocardial blood flow by radiation washout techniques is the inability to localize precisely the origin of radiation in tissue. We developed a new approach for in vivo localization and quantification of regional blood flow. A miniature, silicon, solid-state, avalanche radiation detector, which measures the low-penetrating radiation from commonly availa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 78 2  شماره 

صفحات  -

تاریخ انتشار 1988