Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway.

نویسندگان

  • C Keller
  • F Pühringer
  • J R Brimacombe
چکیده

We studied the size 4 laryngeal mask airway (LMA) to test the hypothesis that oropharyngeal leak pressure and fibreoptic position improves with increasing cuff volume. After LMA insertion, 50 anaesthetized adult patients had the cuff inflated in 5-ml increments to 40 ml. Oropharyngeal leak pressure was optimal at 15 ml and decreased at higher volumes. The fibreoptic position was optimal at 0-20 ml and deteriorated at higher volumes. Gastric insufflation was detected more frequently when the cuff volume exceeded 20 ml. We conclude that inflation of the size 4 LMA to the maximum recommended volume provides suboptimal conditions and that this value should be reduced from 30 to 20 ml.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The laryngeal mask airway Supreme--a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients.

The LMA Supreme is a new extraglottic airway device which brings together features of the LMA ProSeal, Fastrach and Unique. We test the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position and ease of gastric tube placement differ between the LMA ProSeal and the LMA Supreme in paralysed anesthetised patients. Ninety-three females aged 19-71 years were studied. Bot...

متن کامل

Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial

Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis) and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was r...

متن کامل

The influence of head and neck position on oropharyngeal leak pressure and cuff position with the flexible and the standard laryngeal mask airway.

UNLABELLED We conducted a randomized, cross-over study of 20 paralyzed anesthetized adult patients to test the hypothesis that oropharyngeal leak pressure and cuff position (assessed fiberoptically) vary with head and neck position for the flexible (FLMA) and standard laryngeal mask airway (LMA). Both devices were inserted into each patient in random order. Oropharyngeal leak pressure and fiber...

متن کامل

Laryngeal mask airway size selection in males and females: ease of insertion, oropharyngeal leak pressure, pharyngeal mucosal pressures and anatomical position.

We have compared ease of insertion, oropharyngeal leak pressure, directly measured pharyngeal mucosal pressure and anatomical position (assessed fibreoptically) for the size 4 and size 5 laryngeal mask airway (LMA) in 20 male and 20 female patients. Microchip pressure sensors were attached to the LMA at locations corresponding to the piriform fossa, hypopharynx, base of the tongue, lateral and ...

متن کامل

Comparison of Proseal Laryngeal Mask Airway (Proseal LMATM) with I-Gel by Fireoptic View of Glottic Aperture in Anaesthetised Adult Patients

Background: The i-gel, a new supraglottic airway device, has been touted to have acceptable airway seal pressure and better ventilatory parameters than Proseal laryngeal mask airway (PLMA) in adults. We propose to test this hypothesis objectively, by comparing fibreoptic grading of positioning of the above airways in adult patients. Methods: Ninety two adult patients undergoing minor surgeries ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 81 2  شماره 

صفحات  -

تاریخ انتشار 1998