Error Analysis of Clay-Rock Water Content Estimation with Broadband High-Frequency Electromagnetic Sensors - Air Gap Effect
نویسندگان
چکیده
Broadband electromagnetic frequency or time domain sensor techniques present high potential for quantitative water content monitoring in porous media. Prior to in situ application, the impact of the relationship between the broadband electromagnetic properties of the porous material (clay-rock) and the water content on the frequency or time domain sensor response is required. For this purpose, dielectric properties of intact clay rock samples experimental determined in the frequency range from 1 MHz to 10 GHz were used as input data in 3-D numerical frequency domain finite element field calculations to model the one port broadband frequency or time domain transfer function for a three rods based sensor embedded in the clay-rock. The sensor response in terms of the reflection factor was analyzed in time domain with classical travel time analysis in combination with an empirical model according to Topp equation, as well as the theoretical Lichtenecker and Rother model (LRM) to estimate the volumetric water content. The mixture equation considering the appropriate porosity of the investigated material provide a practical and efficient approach for water content estimation based on classical travel time analysis with the onset-method. The inflection method is not recommended for water content estimation in electrical dispersive and absorptive material. Moreover, the results clearly indicate that effects due to coupling of the sensor to the material cannot be neglected. Coupling problems caused by an air gap lead to dramatic effects on water content estimation, even for submillimeter gaps. Thus, the quantitative determination of the in situ water content requires careful sensor installation in order to reach a perfect probe clay rock coupling.
منابع مشابه
Frequency Dependence of the Complex Permittivity and Its Impact on Dielectric Sensor Calibration in Soils
tiveness of TDR. However, the emergence of low-cost, high-frequency oscillators has led to an increased interThe capacitance (CAP) method and time domain reflectometry est in CAP techniques (e.g., Dean et al., 1987; Evett (TDR) are two popular electromagnetic techniques used to estimate soil water content. However, the frequency dependence of the real and Steiner, 1995; Paltineanu and Starr, 19...
متن کاملA Novel Low-Cost Open-Hardware Platform for Monitoring Soil Water Content and Multiple Soil-Air-Vegetation Parameters
Monitoring soil water content at high spatio-temporal resolution and coupled to other sensor data is crucial for applications oriented towards water sustainability in agriculture, such as precision irrigation or phenotyping root traits for drought tolerance. The cost of instrumentation, however, limits measurement frequency and number of sensors. The objective of this work was to design a low c...
متن کاملCorrelated Effect of Air Gap and PVP Concentration on the Structure and Performance of PVDF Ultrafiltration Hollow Fiber Membrane
Polyvinylidene fluoride/polyvinylpyrrolidone (PVDF/PVP) hollow fiber membranes were fabricated by dry-jet wet-spinning process. The correlated effects of the air gap length and PVP concentration ((1) the air gap length effect at the low and high PVP concentration in the dope solutions, as well as (2) the effect of the PVP concentration at the same air gap length) on the cross-section structure ...
متن کاملEstimation of Soil Hydraulic Properties Curve through Beerkan Infiltration Experiment Algorithms
Nowadays, the Beerkan computational algorithms (BESTslope and BESTsteday) are known as the suitable indirect methods for estimating soil saturated hydraulic conductivity (Ks) and sorptivity (S), as well as the scale parameter (hg) in van Genuchten soil water retention equation through the data collected in the Beerkan infiltration experiment and other required data. The purpose of this study wa...
متن کاملNumerical Analysis of Photonic Crystal Waveguide
During the last decade, a major research interest is focused on optical sensors for chemical and biosensing application relaying on refractive index (RI) measurements. Among this class of optical sensors the waveguides confined inside of photonic crystals are of high interest. The application of such RI optical sensors is interesting for both gaseous and aqueous samples and includes measurement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Sensors
دوره 16 4 شماره
صفحات -
تاریخ انتشار 2016