Importance of pre-analytical factors contributing to measurement uncertainty, when determining sulfadoxine and sulfamethoxazole from capillary blood dried on sampling paper.

نویسندگان

  • M Malm
  • J Lindkvist
  • Y Bergqvist
چکیده

A bioanalytical method is developed and validated for determination of sulfadoxine (SD) and sulfamethoxazole (SM) in 100 microL capillary blood dried on sampling paper (Whatman 31ET Chr). SD and SM are extracted with 2000 microL perchloric acid and the liquid phase is loaded onto ENV+ solid-phase extraction columns. SD, SM, and the internal standard are separated on a Purospher STAR RP-18 liquid chromatography column (150 x 4.6 mm) with a mobile phase consisting of acetonitrile-sodium acetate buffer pH 5.2, I = 0.1 (33:67, v/v). Analytes are detected with UV at 256 nm. Lower limit of quantitation is 5 micromol/L, where precisions are 4.2% and 3.9% for SD and SM, respectively. Three brands of sampling papers have been compared with respect to absorption properties, extraction recoveries, and variations. Punching out dried blood spots (DBS) instead of cutting spots into strips prior to extraction has been evaluated by examining precision and accuracy of SD and SM determinations. Importance of uniformity of types of sampling paper, sampling volume and biological matrix, benefit of punching out discs from DBS, and impact on absorption properties of different brands of sampling papers are discussed. Avoiding pre-analytical errors whenever possible results in concentrations determined being more accurate and precise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of dried blood spot sampling for the measurement of HbA1c: a cross-sectional study

BACKGROUND The use of dried blood spot (DBS) sampling is an alternative to traditional venous blood collection, and particularly useful for people living in rural and remote areas, and for those who are infirm, house-bound or time-poor. The objective of this study was to assess whether the measurement of glycated haemoglobin A1c (HbA1c) in DBS samples provided comparative and acceptably precise...

متن کامل

Evaluation of Hemoglobin Concentration of Cord, Capillary and Venous sampling in Neonates

Abstract Background Anemia is one of the most common abnormalities in pediatric medicine. Considerable differences are seen in the peripheral blood indices of infants in developing countries. The aim of this study was to determine and compared blood hemoglobin concentration in three sites of sampling in neonate. Materials and Methods 1600 term and preterm new infant in three sites of sampli...

متن کامل

Personality-Cognitive Correlates of Social Phobia: Mediator Role of Intolerance of Uncertainty

Objective: Social phobia is considered as one of the most common anxiety disorders. The researchers have been looking for the basic mechanism behind it, since determining these factors can be influential in prevention and treatment. In recent years, some of the most important personality and cognitive correlates of social phobia including neuroticism, fear of negative evaluation, anxiety sensit...

متن کامل

Potential of Dried Blood Self-Sampling for Cyclosporine C2 Monitoring in Transplant Outpatients

Background. Close therapeutic drug monitoring of Cyclosporine (CsA) in transplant outpatients is a favourable procedure to maintain the long-term blood drug levels within their respective narrow therapeutic ranges. Compared to basal levels (C(0)), CsA peak levels (C(2)) are more predictive for transplant rejection. However, the application of C(2) levels is hampered by the precise time of blood...

متن کامل

Fuzzy analytical network process logic for performance measurement system of e-learning centers of universities

This paper proposes an efficient performance measurement system to evaluate the excellence of e-learning centers of universities. The proposed system uses the analytic network process (ANP) as an effective multi-criteria decision making (MCDM) method and its fuzzy mode to respond to uncertainties in judgements. This system also needs a targeted and systematic criteria set which is collected thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 46 10  شماره 

صفحات  -

تاریخ انتشار 2008