Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws.

نویسندگان

  • Marcus Richter
  • Balkan Cakir
  • René Schmidt
چکیده

STUDY DESIGN Prospective clinical study with postoperative radiologic control of pedicle screw placement in the cervical spine. OBJECTIVES To evaluate whether cervical pedicle screws can be placed safely in a conventional technique when using cannulated screws and separate stab incisions. Also, to evaluate if accuracy and safety of pedicle screw placement can be improved using a computer-assisted surgery (CAS) system (VectorVision; BrainLAB AG, Heimstetten, Germany). SUMMARY OF BACKGROUND DATA Pedicle screws are rarely used in the cervical spine compared to the use in lumbar and thoracic spine. The main reason is probably the potential risk of iatrogenic damage to the spinal cord, nerve roots, or vertebral artery caused by screw misplacement as well as the more demanding technique of pedicle screw placement in the cervical spine. METHODS A total of 52 consecutive patients with posterior cervical or cervicothoracic instrumentations using pedicle screws were evaluated prospectively. For the first 20 patients, 93 pedicle screws were implanted using the conventional technique with the image intensifier in the lateral view, and for the next 32 patients (167 screws), a CAS system was additionally used. For registration of the vertebra, surface-matching algorithms were used. For evaluation of screw placement, postoperative computerized tomography with multiplanar reconstructions in the screw axis was performed for each screw. RESULTS No implant-related complications were observed. No neurologic or vascular complications were found related to pedicle screws. The rate of pedicle perforations was 8.6% (8 screws) in the conventional group and 3.0% (5 screws) in the CAS group, and in all cases, less than 2-mm displacement. None of the screws with pedicle perforation had to be revised as a result of nonsufficient biomechanical stability or compression of neural/vascular structures. CONCLUSIONS Transpedicular screws in the cervical spine and cervicothoracic junction can be applied safely and with high accuracy in a conventional technique. Cannulated screws and the use of separate stab incisions from C3-C6 with a trocar system allow for reduced screw misplacement rates. The CAS system leads to significantly reduced screw misplacement rates. Therefore, because of the potential risk of injury to the vertebral artery and neural elements, the use of a CAS system seems to be beneficial, especially for pedicle instrumentation C3-C6.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws.

STUDY DESIGN Randomized laboratory cadaver study. OBJECTIVE The objective of this study was to determine the accuracy of anterior transpedicular screw placement in the cervical spine using conventional fluoroscopy versus computer-assisted navigation. SUMMARY OF BACKGROUND DATA Traditionally, global cervical instability has required anterior and posterior fixation due to the superior biomech...

متن کامل

Computer-Aided Surgery Does Not Increase the Accuracy of Dorsal Pedicle Screw Placement in the Thoracic and Lumbar Spine: A Retrospective Analysis of 2,003 Pedicle Screws in a Level I Trauma Center

Study Design A retrospective analysis of a prospective database. Objective Meta-analyses suggest that computer-assisted systems can increase the accuracy of pedicle screw placement for dorsal spinal fusion procedures. The results of further meta-analyses report that in the thoracic spine, both the methods have comparable placement accuracy. These studies are limited due to an abundance of screw...

متن کامل

Accuracy of Pedicle Screw Insertion Using Fluoroscopy-Based Navigation-Assisted Surgery : Computed Tomography Postoperative Assessment in 96 Consecutive Patients

OBJECTIVE Two-dimensional fluoroscopy-based computerized navigation for the placement of pedicle screws offers the advantage of using stored patient-specific imaging data in providing real-time guidance during screw placement. The study aimed to describe the accuracy and reliability of a fluoroscopy-based navigation system for pedicle screw insertion. METHODS A total of 477 pedicle screws wer...

متن کامل

Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and a cannulated tapping device

BACKGROUND Pedicle screw insertions are commonly used for posterior fixation to treat various spine disorders. However, the misplacement of pedicle screws can lead to disastrous complications. Inaccurate pedicle screw placement is relatively common even when placement is performed under fluoroscopic control. In order to improve the accuracy of the screw placement, we applied a technique using g...

متن کامل

Possible usage of cannulated pedicle screws without cement augmentation

BACKGROUND: The use of pedicle screws is becoming increasingly popular for spinal surgery practice as the technology advances. Screw pullout due to bone quality and loading conditions is one of the most common problems observed after pedicle screw fixation. Several solutions were studied to prevent screw pullout. These can be investigated under three main categories: screw design, expandable sc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 30 20  شماره 

صفحات  -

تاریخ انتشار 2005