SU-E-T-73: Investigation of 3D Dosimetry for Proton Therapy Using PRESAGE.
نویسندگان
چکیده
PURPOSE This investigation studies the feasibility of PRESAGE, a 3D polyurethane dosimeter, for relative dosimetry measurements of clinically relevant proton treatments using an anthropomorphic head phantom developed by the Radiological Physics Center (RPC). Performance of a low-LET dependent PRESAGE was evaluated by comparison to the traditionally used radiochromic film, EBT2, and thermoluminescent dosimeters (TLDs). METHODS The head phantom consists of a human skeleton with synthetic isocyanate rubber having similar tissue-equivalent radiological properties to high-energy protons cast around it to mimic natural heterogeneous anatomical structures. The phantom has a cutout that admits either a film and TLD insert or a PRESAGE dosimeter. A treatment plan was developed and delivered twice: once with the film/TLD insert and again with the PRESAGE dosimeter. The 3D dose distribution from the PRESAGE was read out using the Duke medium-field-of-view optical-CT scanner (DMOS). The measured dose distributions were compared to the treatment plan and the distance to agreement (DTA) within the high dose regions was calculated in the sagittal and coronal planes as measured by the EBT2 film. RESULTS PRESAGE dose profiles showed agreement within 3mm and 4mm in the coronal and sagittal planes respectively. Film data showed agreement to 2mm in both planes. A 2D gamma comparison between the PRESAGE and planning data gave 95% agreement with 5%/3mm and 5%/4mm in those respective fields. CONCLUSION PRESAGE dosimeters show great potential for measuring dose distributions from proton fields within heterogeneous volumes, with the opportunity to measure volumetric dose data. Data within the high dose regions of the treatment showed comparable DTAs from two dosimetry systems. With film measurements confirming PRESAGE readings, dose data in low dose regions in clinically sensitive regions can now be better determined. Additional work will include organs at risk (OAR) considerations allowing for detailed DVH comparisons, as well as 3D gamma analysis. NIH grant 5R01CA100835.
منابع مشابه
Protons & Carbon Therapy
Monte Carlo water-equivalence study of two PRESAGE® formulations for proton beam dosimetry T Gorjiara, Z Kuncic, J Adamovics and C Baldock 2013 J. Phys.: Conf. Ser. 444 012090 PRESAGE® is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE® formulations irra...
متن کاملMonte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry
PRESAGE is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE formulations irradiated by a 62 MeV proton beam were compared with that in water using GEANT4 Monte Carlo simulations. The dose delivered by secondary particles was also calculated. Our results s...
متن کاملHow feasible is remote 3D dosimetry for MR guided Radiation Therapy (MRgRT)?
To develop and apply a remote dosimetry protocol with PRESAGE® radiochromic plastic and optical-CT readout in the validation of MRI guided radiation therapy (MRgRT) treatments (MRIdian® by ViewRay®). Through multi-institutional collaboration we performed PRESAGE® dosimetry studies in 4ml cuvettes to investigate dose-response linearity, MRcompatibility, and energy-independence. An open calibrati...
متن کاملSU-E-T-132: Investigation of Photon and Proton Overlapping Fields in PRESAGE- Dosimeters.
PURPOSE To evaluate the effects of overlapping dose volumes for varying field arrangements in two formulations of PRESAGE®: one intended for, and irradiated with, proton beams and the other photon beams. METHODS For each treatment modality (photon, proton), three overlapping field setups were performed. These included a stationary dosimeter irradiated over six fractions, a dosimeter shifted l...
متن کاملInvestigating the Feasibility of 3D Dosimetry in the RPC IMRT H&N Phantom.
An urgent requirement for 3D dosimetry has been recognized because of high failure rate (~25%) in RPC credentialing, which relies on point and 2D dose measurements. Comprehensive 3D dosimetry is likely to resolve more errors and improve IMRT quality assurance. This work presents an investigation of the feasibility of PRESAGE/optical-CT 3D dosimetry in the Radiologic Physics Center (RPC) IMRT H&...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 40 6Part11 شماره
صفحات -
تاریخ انتشار 2013