Technical note: a device for obtaining time-integrated samples of ruminal fluid.
نویسندگان
چکیده
A device was adapted to allow for time-integrated sampling of fluid from the rumen via a cannula. The sampler consisted of a cup-shaped ceramic filter positioned in the ventral rumen of a cannulated cow and attached to a tube through which fluid entering the filter was removed continuously using a peristaltic pump. Rate of ruminal fluid removal using the device was monitored over two 36-h periods (at 6-h intervals) and was not affected (P > .05) by time, indicating that the system was not susceptible to clogging during this period. Two cows having ad libitum access to a totally mixed ration were used in a split-block design to evaluate the utility of the system for obtaining time-integrated samples of ruminal fluid. Ruminal fluid VFA concentration and pattern in samples collected in two replicated 8-h periods by the time-integrated sampler (at 1-h intervals) were compared with composite samples collected using a conventional suction-strainer device (at 30-min intervals). Each 8-h collection period started 2 h before or 6 h after feeding. Results indicated that total VFA concentration was not affected (P > .05) by the sampling method. Volatile fatty acid patterns were likewise unaffected (P > .05) except that acetate was 2.5% higher (P < .05) in samples collected 2 h before feeding and valerate was 5% higher (P < .05) in samples collected 6 h after feeding by the suction-strainer device. Although significant, these differences were not considered physiologically important. We concluded that use of the ceramic filter improved the sampling of ruminal fluid by simplifying the technique and allowing time-integrated samples to be obtained.
منابع مشابه
A Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)
This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...
متن کاملIntegrated Approach for Cellular Manufacturing a Case Study (TECHNICAL NOTE)
To cope with fast changing customer requirements, industrial demands and to meet stringent specifications of customers Cellular Manufacturing Systems has become an effective tool in hands of manufacturers. Most of the published literature on cell formation earlier considers only the data available in the route sheets and ignored subproblems associated with cell formation. There is a need to dev...
متن کاملThe Opportunities Afforded by Embedded Computer Systems for Monitoring and Control of Industrial Processes in Less-Industrialised Countries (TECHNICAL NOTE)
The dramatic changes in integrated-circuit technology over the last two decades have been of great benefit to countries such as Zimbabwe. High volume production of VLSI chips has produced a supply of intelligent, versatile electronic processing devices at very low cost. In particular the facilities of the microcontroller have steadily developed to the accompaniment of a reduction in price. Sinc...
متن کاملTwin Plate Weir: A Flow Measuring Device (TECHNICAL NOTE)
For efficient use of water, accurate measurement of flow in (field/laboratory) channels is required for many water resource projects. The present work is aimed to study the flow characteristics of a twin plate weir (two sharp-crested plates are placed one behind the other at some distance) under free and submerged flow conditions. Experiments are performed with four spacing of the twin plate we...
متن کاملSeismic Mitigation of Building Frames using Magnetorheological Damper (TECHNICAL NOTE)
The present study focusses on the damping force control of shear mode magnetorheological (MR) damper for seismic mitigations. Therefore, the semi-active MR damper which can control the vibration is analyzed both experimentally and numerically. Carbonyl iron is used as the magnetic particle and Castrol Magnetec oil as carrier fluid throughout the study. MR damper is designed and fabricated, and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of animal science
دوره 77 9 شماره
صفحات -
تاریخ انتشار 1999