Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometry.
نویسندگان
چکیده
Energy-sensitive calorimetric detectors that operate at low temperatures ("cryogenic detectors") have recently been applied for the first time as ion detectors in time-of-flight mass spectrometry. Compared to conventional, ionization-based detectors, which rely on secondary electron formation or the charge created in a semiconductor, cryogenic detectors measure low-energy solid state excitations created by a particle impact. This energy sensitivity of cryogenic detectors results in several potential advantages for TOF-MS. Cryogenic detectors are expected to have near 100% efficiency even for very large, slow-moving molecules, in contrast to microchannel plates whose efficiency drops considerably at large mass. Thus, cryogenic detectors could contribute to extending the mass range accessible by TOF-MS and help improving detection limits. In addition, the energy resolution provided by cryogenic detectors can be used for charge discrimination and studies of ion fragmentation, ion-detector interaction, and internal energies of large molecular ions. Cryogenic detectors could therefore prove to be a valuable diagnostic tool in TOF-MS. Here, we give a general introduction to the cryogenic detector types most applicable to TOF-MS including those types already used in several TOF-MS experiments. We review and compare the results of these experiments, discuss practical aspects of operating cryogenic detectors in TOF-MS systems, and describe potential near future improvements of cryogenic detectors for applications in mass spectrometry.
منابع مشابه
Cryogenic Detector Development at LLNL: Ultraviolet, X-ray, Gamma-ray and Biomolecule Spectroscopy
We are developing low-temperature detectors for optical, ultraviolet, X-ray, and gamma-ray spectroscopy, and for biomolecular mass spectrometry. We present here a survey of our recent work in developing these detectors and some of the first results in applying these detectors for materials analysis and biomolecular mass spectrometry. We have measured thin-film Nb/Al/Al2O3/Al/Nb superconducting ...
متن کاملCompleting our Universe: Direct Detection of Dark Matter with Cryogenic Liquid Noble Gases
Leading postulations in supersymmetry indicate that the Weakly Interacting Massive Particle (WIMP) accounts for the bulk of mass observed as dark matter in the Universe. Cryogenic liquid noble detectors are expected to discover these particles within the next two years. This experiment investigates the limits of detectors designed around the XENON10 prototype in determination of WIMP mass and i...
متن کاملHigh-energy resolution alpha spectrometry using cryogenic detectors.
Applications such as environment monitoring implying alpha emitters activity measurement associated with isotope identification, require high-energy resolution detectors. Conventional silicon detectors are inexpensive therefore widely used, although intrinsically limited in energy resolution. Thermal detection principle of cryogenic detectors introduces a breakthrough in alpha particle measurem...
متن کاملDirect measurement of product of the electron mobility and mean free drift time of CdZnTe semiconductors using position sensitive single polarity charge sensing detectors
Related Articles A new detector for mass spectrometry: Direct detection of low energy ions using a multi-pixel photon counter Rev. Sci. Instrum. 83, 013304 (2012) A transport-based model of material trends in nonproportionality of scintillators J. Appl. Phys. 109, 123716 (2011) A digital method for separation and reconstruction of pile-up events in germanium detectors Rev. Sci. Instrum. 81, 103...
متن کاملSingle-molecule mass spectrometry.
In single-molecule mass spectrometry, the mass of each ion is measured individually; making it suitable for the analysis of very large, heterogeneous objects that cannot be analyzed by conventional means. A range of single-molecule mass spectrometry techniques has been developed, including time-of-flight with cryogenic detectors, a quadrupole ion trap with optical detection, single-molecule Fou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Mass spectrometry reviews
دوره 18 3-4 شماره
صفحات -
تاریخ انتشار 1999